Pre-pressurized reference cells and extreme thermal resistance (0–130°C) tailored for high-salinity water reuse, pharmaceutical sterilization, and petrochemical processing across Riyadh's Industrial Cities.
Under the Saudi National Industrial Development and Logistics Program (NIDLP) and Vision 2030, Riyadh is rapidly transitioning into a high-technology industrial, pharmaceutical, and chemical powerhouse.
Riyadh’s 2nd and 3rd Industrial Cities host high-capacity petrochemical blending, specialty polymer fabrication, and metallurgical facilities. These continuous operations demand inline pH and ORP monitoring capable of handling volatile solvents, strong acids, and process temperatures reaching up to 130°C without drifting or salt-bridge clogging.
Given the arid climate of the Najd plateau, industrial facilities in Riyadh rely heavily on thermal evaporation, Multi-Stage Flash (MSF) distillers, and Zero Liquid Discharge (ZLD) crystallization systems. Our high-temperature sensors withstand hypersaline slurries and caustic scaling where standard reference probes perish.
The Sudair City for Industry and Businesses, adjacent to Riyadh, serves as the regional hub for sterile manufacturing, vaccine synthesis, and microbial fermentation. Inline probes require repeated SIP (Steam-In-Place) and CIP (Clean-In-Place) endurance at 121–135°C without compromising mV slope integrity.
Conventional pH glass membranes and Ag/AgCl reference cells suffer rapid junction fouling, electrolyte leaching, and resistance drift under elevated thermal gradients. BOQU's specialized designs solve these failure modes.
| Engineering Parameter | Standard Commercial Sensors | BOQU High-Temp Industrial Probes | Impact on Riyadh Plant Operation |
|---|---|---|---|
| Operating Temperature | 0 to 60°C (Unstable above 70°C) | 0 to 130°C (Steam Sterilizable to 135°C) | Eliminates frequent sample cooling loops and chiller capital cost. |
| Reference System | Liquid KCl with single ceramic pinhole | Dual-junction polymerized solid gel + annular porous Teflon | Prevents heavy-metal sulfide poisoning (S²⁻, CN⁻) and junction clogging. |
| Glass Membrane Matrix | Soft low-impedance soda lime glass | Specially formulated heavy-duty lithium silicate glass | Resists aggressive alkali etching and mechanical abrasion at 100°C+. |
| Pre-Pressure Resistance | Atmospheric (up to 1.5 Bar) | Pre-pressurized up to 6–16 Bar | Stops process fluid backflow into the reference electrode cell. |
| Digital Protocol | Raw mV high-impedance analogue | Internal micro-transmitter with RS485 Modbus RTU | Immune to electromagnetic noise from large VFD pumps and turbine halls. |
From district cooling mega-plants across the Riyadh metropolitan area to closed-loop chemical distillation, our field-proven hardware integrates into DCS/SCADA architectures.
Riyadh's vast central chiller plants require continuous biocide dosing and scaling monitoring. Our ORP sensors regulate oxidizing biocide injection (chlorine dioxide, sodium hypochlorite) while dual pH/EC controllers preserve heat exchanger efficiency against calcium carbonate precipitation.
Thermal power utilities operating around the Central Province utilize our Steam and Water Analysis System (SWAS) sensors. Low-drift high-temperature pH and cation conductivity sensors safeguard superheaters and steam turbines from catastrophic stress corrosion cracking.
Riyadh's primary steel fabrication and electroplating workshops generate hot, acidic rinse waters laden with hexavalent chromium and heavy metals. High-temperature ORP reduction control and two-stage pH neutralization loops operate autonomously without sensor poisoning.
Headquartered in Shanghai with dual advanced production facilities across Kangqiao and Lingang, BOQU provides international EPCs and Riyadh distributors direct-from-source wholesale dependability.
Equipped with automated glass-blowing lathes, constant-temperature chemical reaction vessels for electrolyte synthesis, and class-10,000 clean rooms for membrane assembly.
Every high-temperature sensor batch undergoes continuous 130°C cycling and autoclave stress testing to eliminate early life electrochemical degradation before packaging.
Unmatched wholesale volume capacity enables rapid buffer stock deployments for Saudi master distributors, EPC contractors, and OEM instrumentation brands.
Fully certified to ISO 9001, ISO 14001, CE, SGS, and FDA biocompatibility standards. pH5806 holds the prestigious Shanghai Brand certification for engineering excellence.
Importing industrial measuring instruments into Saudi Arabia demands strict conformity with the Saudi Standards, Metrology and Quality Organization (SASO).
We facilitate streamlined issuance of the Certificate of Conformity (PCoC) and Shipment Certificate of Conformity (SCoC) via the SABER platform, ensuring zero customs bottlenecks at King Khalid International Airport (RUH) or Riyadh Dry Port.
From PG13.5 and 3/4" NPT process connections in 316L Stainless Steel, Titanium, or Hastelloy C276 to custom cable lengths with VP8/S8 high-temperature connectors, our OEM programs suit regional specifications.
Each wholesale batch is supplied with factory calibration certificates traceable to NIST standards, full material test reports (MTR), and comprehensive operating manuals in both English and Arabic upon request.
Explore our full manufacturing line of industrial electrodes, field transmitters, and autoclaving probes specified for Riyadh utilities, industrial operators, and system vendors.
A rigorous, transparent procurement pipeline designed for international trade compliance, technical validation, and rapid shipment release.
Submit medium chemistry, temperature curves, operating pressure, and existing piping schematics. Our engineers match the optimal glass impedance and reference junction.
Evaluation units shipped directly to your Riyadh testing plant via DHL/FedEx within 3 to 5 business days for bench or pilot verification.
Automated assembly, precision gel degassing, pressurized helium leak detection, and 48-hour thermal chamber validation under ISO 9001 quality supervision.
Issuance of SABER documentation, legalized commercial invoices, and consolidated air or sea freight direct to Dammam, Jeddah, or Riyadh dry ports.
Authoritative technical answers from BOQU's senior electrochemical research specialists.
Standard sensors use liquid electrolytes that experience high vapor pressures at temperatures exceeding 60°C. This causes the internal KCl electrolyte to expand, flush out through porous ceramic diaphragms, and foul the Ag/AgCl reference pin. BOQU’s high-temperature sensors employ a pre-pressurized solid polymer matrix that maintains a balanced internal osmotic pressure up to 130°C and 16 Bar.
Yes. Our sensors are supplied either with standard high-impedance coaxial cables (S8, VP8, or K8 connectors) matching existing analog transmitters, or with integrated smart RS485 Modbus RTU microprocessors that link directly to PLC, SCADA, or cloud telemetry panels without requiring intermediary transmitters.
Under repeated SIP (Steam-In-Place) procedures at 121°C–130°C (30–45 minutes per cycle), the pH5806 is rated for more than 50 continuous steam cycles before slope calibration adjustments fall below 92%, substantially exceeding conventional glass electrode longevity.
BOQU coordinates directly with accredited third-party certification bodies (such as SGS, Intertek, or TÜV) to register products on the Saudi SABER portal. We furnish test reports and factory inspection certificates required for the automatic release of Shipment Certificates (SCoC).