Delivering steam-sterilizable, pressure-resistant, and chemically robust electrochemistry electrodes engineered for Thailand's Eastern Economic Corridor (EEC), Greater Bangkok biochemical processing plants, and food-grade fermentation facilities.
Pre-pressurized, polymeric gel electrolyte systems engineered for SIP steam cycles (130°C/140°C), aggressive caustic Clean-in-Place (CIP), and volatile industrial process fluids across Bangkok and surrounding industrial provinces.
Built with ultra-durable low-alkali error glass and a solid polymer electrolyte to prevent ion poisoning during high-temperature sugar refining and food processing across Bangkok.
Explore Sensor Model →
Features an industry-standard PG13.5 process connection and IP68 S8 coaxial head, offering seamless drop-in replacement for European imports in Bangkok pharmaceutical tanks.
Explore Sensor Model →
Specialized electrolyte reference designed with an integrated silver-ion trap, preventing sulfide precipitation and drift during prolonged aerobic fermentation batches in Pathum Thani.
Explore Sensor Model →
Combines potentiometric pH measurement with high-precision internal Pt100/Pt1000 RTD sensing for real-time automatic Nernst temperature compensation under dynamic thermal fluctuations.
Explore Sensor Model →From the food & bio-processing facilities in Nakhon Pathom and Samut Prakan to petrochemical integration in the EEC periphery, high-temperature fluid monitoring faces extreme operating stress.
Thailand ranks among the world's leading sugar and cassava exporters. In mills along the central Chao Phraya river basin and outer Bangkok districts, clarification and carbonation processes operate continuously at 75°C to 105°C. Conventional glass sensors suffer rapid alkaline error and diaphragm clogging from calcium and polysaccharide deposition. Our sensors utilize double-junction ceramic and open annular polymer channels that resist scaling.
Industrial biotech estates in Pathum Thani and Lat Krabang demand repeated Steam-In-Place (SIP) sterilization at 121°C–130°C without sensor removal. Frequent steam exposure causes electrolyte outflow and thermal drift in legacy sensors. BOQU's proprietary pre-pressurized gel reservoirs maintain positive overpressure across the ceramic porous junction, suppressing boiling-induced bulb dehydration.
The Department of Industrial Works (DIW) enforces strict discharge limits for BOD, COD, and heavy metals. Textile dyeing, metal plating, and chemical synthesizing plants in Samut Sakhon discharge hot effluent (55°C–80°C) with aggressive redox conditions. Our ORP sensors with solid platinum rings and poisoning-resistant reference systems enable stable real-time dosing of sodium bisulfite and hypochlorite.
Combining world-class electrochemistry research, scalable automated fabrication, and direct RCEP tariff efficiencies to outperform legacy Western instrumentation brands.
BOQU established one of the industry's dedicated high-temperature water quality sensor laboratories. Every batch of pH and ORP glass membranes undergoes dynamic autoclave cycling testing (0°C to 135°C thermal shock), high-pressure leakage simulation (up to 1.0 MPa), and long-term chemical resistance verification. This empirical data ensures that when an electrode lands at Suvarnabhumi Airport and is deployed into an aseptic fermenter, its calibration slope remains within >97.5% of theoretical Nernstian performance.
Process plants in Bangkok frequently endure 8-to-16-week delivery lead times and premium markups from European instrumentation distributors. Operating directly from our Shanghai manufacturing headquarters, BOQU delivers standard and custom OEM electrodes to Bangkok within 5 to 7 business days under the Regional Comprehensive Economic Partnership (RCEP) trade framework with preferential customs tariffs. Engineering buyers achieve a 40% to 60% reduction in consumable sensor replacement costs while eliminating unplanned plant downtime.
Engineered to eliminate reference electrode poisoning, thermal hysteresis, glass leaching, and high-impedance drift across high-temperature Bangkok industrial media.
| Performance Specification | BOQU High-Temp Series (pH5806 / S8 / ATC) | Standard Commercial Sensors | Engineering Benefit in Bangkok Plants |
|---|---|---|---|
| Operating Temperature | 0 to 130°C (Steam Sterilizable up to 135°C) | 0 to 60°C (Occasional 80°C Max) | Withstands autoclaving and direct inline CIP/SIP cycles without replacement. |
| Process Pressure Limit | Up to 0.6 MPa (6 Bar) Pre-pressurized | 0.1 to 0.2 MPa (Unpressurized) | Prevents process fluids from backing up into the reference junction. |
| Glass Membrane Formula | Proprietary Low-Alkali-Error Heavy Glass | Standard Soft Sodium Glass | Eliminates alkaline ion error above pH 11.0 at elevated temperatures. |
| Reference System | Long-path Ag/AgCl with Ag+ Scavenging Trap | Direct Single-junction Ag/AgCl | Resists sulfide, protein, and heavy metal poisoning in bio-broths. |
| Electrolyte Medium | Polymerized High-Viscosity Gel (KCl Saturated) | Aqueous Liquid KCl Solution | Zero electrolyte leakage, negligible dilution, inverted mounting safe. |
| Connector / Mounting | Standard S8 / VP / K9 with PG13.5 Thread | Fixed Cable or Non-standard Threads | Direct retrofit into Mettler-Toledo, Endress+Hauser, and Hamilton flow assemblies. |
| Signal Architecture | High-Z Analog or Direct RS485 Modbus RTU | Low-Shield Analog Only | Enables 500m noise-free digital telemetry straight to Siemens or Omron PLCs. |
Detailed process layouts showing how BOQU inline analyzers integrate into primary processing stations across Thailand's heavy industry sectors.
In food and beverage packaging plants across Pathum Thani, Clean-in-Place systems circulate 2% NaOH at 85°C followed by nitric acid sanitization. By pairing the BOQU pH5806 with our SJG-2083CS Concentration Monitor, plants achieve automated reagent dosing with millivolt-level accuracy, lowering raw caustic consumption by 18% while guaranteeing microbiological sanitation compliance.
Cassava-based bio-ethanol production requires maintaining mash broth pH strictly between 4.2 and 4.6 while yeast fermentation releases heat and organic volatile acids. BOQU's high-temperature fermentation sensors maintain zero-drift potentiometric readings over 120-hour batches, preventing yeast cell lysis and maximizing conversion yield per metric ton of raw starch.
Cogeneration power plants in the Rayong-Bangkok corridor require precise monitoring of boiler condensate return (typically 60°C–95°C) with conductivity below 0.1 µS/cm and pH controlled between 8.8 and 9.3 via amine dosing. BOQU SWAS (Steam & Water Analysis System) electrodes prevent boiler tube scaling, caustic embrittlement, and unscheduled turbine overhauls.
We supply white-label electrochemistry modules, custom stem lengths, specialized cable shielding, and private firmware interfaces for international system integrators.
Standard glass sensor insertion lengths range from 120mm to 425mm. We fabricate custom titanium, 316L stainless steel, or PVDF retractable wet-tap insertion assemblies (retractors) that permit sensor withdrawal for cleaning and buffer calibration during ongoing plant operations under full system line pressure.
Upgrade legacy 4-20mA loops to modern smart factory communications. Our IoT-485 sensors package signal conditioning, A/D conversion, calibration curve memory, and RS485 Modbus RTU registers directly inside the sensor head, connecting straight to PLCs, SCADA screens, or industrial wireless IoT gateways.
For regional instrumentation distributors across Southeast Asia, BOQU provides end-to-end private brand development. This includes customized laser-etched logos, part numbers, customized cable colors, multi-language data sheets, and custom-molded protective shipping packaging.
In-depth electrochemistry answers for chemical managers, maintenance supervisors, and procurement leads in Thailand.
Elevated temperatures (above 70°C) accelerate three distinct degradation mechanisms in electrochemistry electrodes:
1. Glass Leaching: Standard glass membranes experience rapid alkali-metal ion exchange, stripping the sensitive hydrated gel layer and causing response sluggishness and flat slopes.
2. Electrolyte Thermal Expansion: Temperature increases cause reference electrolyte expansion and pressure build-up, leading to massive electrolyte loss through the diaphragm. Once cooled, process fluid is sucked back into the reference chamber, poisoning the silver/silver chloride (Ag/AgCl) wire.
3. Reference Potential Shift: Standard aqueous KCl loses saturation at high temperatures, creating severe calibration drift. BOQU solves these challenges by combining low-impedance high-temperature glass, pre-pressurized solid polymer electrolyte matrices, and integrated silver ion traps.
Yes. BOQU manufactures high-temperature pH and ORP sensors with standardized mechanical and electrical connections identical to Mettler-Toledo, Hamilton, Endress+Hauser, and Broadley-James. Our models feature metric PG13.5 process threads, 120mm, 225mm, 325mm, and 425mm glass shaft lengths, and universal S8, VP, or K8 coaxial connectors.
They drop directly into your existing static or retractable weld-in sockets with zero modification required on your fermenters, reactor vessels, or pipe tees.
According to the Nernst Equation: E = E0 - (2.303 * R * T / F) * pH, the electrode slope changes from 54.20 mV/pH at 0°C to 59.16 mV/pH at 25°C, and rises to 80.01 mV/pH at 130°C. Without accurate temperature compensation, a process reading at 100°C can drift by more than 1.5 to 2.0 pH units.
BOQU models embed high-accuracy Pt100 or Pt1000 Class-A RTDs directly beneath the glass pH-sensing bulb. Our online analyzers continuously sample both millivolt potential and exact resistance, recalculating slope in real-time to guarantee 0.01 pH measurement fidelity across the entire thermal span.
In typical dairy, brewing, and biopharma plants undergoing daily caustic/acid CIP cycles (e.g., 2% caustic soda at 80°C for 45 minutes followed by sanitizing acid rinses), standard sensors often fail within 3 to 6 weeks due to reference poisoning and glass destruction.
BOQU high-temperature polymer sensors deliver an average operating lifespan of 6 to 12 months under identical cycle intensity. Utilizing our auto-cleaning ultrasonic or jet wash assemblies can extend continuous electrode life beyond 14 months.
BOQU provides complete import documentation for Thai industrial customs clearance, including:
1. Certificate of Origin under RCEP Form (securing 0% or reduced customs import duty for Thai buyers).
2. Factory Calibration & Inspection Certificates traceable to NIST/ISO standards.
3. CE conformity certificates, RoHS documentation, and FDA materials safety certificates for biopharma applications.
We provide daily express air cargo (DHL, FedEx, SF International) with delivery to Bangkok within 3 to 5 business days, as well as ocean freight consolidation to Bangkok Port (Klong Toey) and Laem Chabang.
Explore our complete manufactured catalog of high-temperature online sensors, certified and ready for dispatch to Thai and global industrial facilities.
Full-spectrum high-temperature glass sensor optimized for thermal stability and high-alkalinity resistance in bio-refining lines.
View Product Details →
Universal standard S8 threaded connection engineered for quick disassembly and steam autoclave cycles in cleanroom facilities.
View Product Details →
Certified non-cytotoxic polymer electrolyte electrode that prevents contamination during cell culture and enzyme brewing.
View Product Details →
Built-in Pt100/Pt1000 thermal resistor allows automated slope adjustment under fluctuating temperatures in industrial boilers.
View Product Details →
High-viscosity polymer gel system engineered for continuous slurry, pulp, and wastewater treatment processes.
View Product Details →
Features high mechanical shock resistance and gold-plated coaxial contact pins for minimal signal attenuation.
View Product Details →
Features an ion-trap barrier system preventing sulfur and cyanide ions from reaching the Ag/AgCl reference pin.
View Product Details →
Integrated temperature measurement for dynamic chemical dosing loops in metal finishing, textile dying, and SWAS.
View Product Details →Discuss your operational temperature, pressure, medium composition, and mounting requirements with our application engineers. We provide technical recommendations, CAD integration drawings, and competitive direct-factory quotations within 24 hours.
Send Inquiry Now — Direct Factory Engineering Team