Engineered by Shanghai BOQU Instrument Co., Ltd. for mission-critical liquid monitoring. Each sensor undergoes stringent pre-shipment aging, high-temperature calibration, and electro-chemical impedance diagnostics.
Equipped with pressurized gel electrolytes and high-temperature glass formulations for ultra-pure conditioning skids and fermentation reactors.
View Specifications
Certified for operating extremes from 0 to 130°C. Engineered with polymeric junctions to completely prevent reference poisoning and thermal drift.
View Specifications
Internal PT1000/NTC30K RTD temperature probe with fast thermal reaction time for dynamic high-purity aqueous compensation algorithms.
View Specifications
SIP and CIP autoclavable design for pure bioprocess fluids, complying strictly with FDA and hygienic pharmaceutical validation protocols.
View Specifications
Shanghai Brand certified electrode designed for bioreactors and aggressive pure water loop sanitization cycles up to 135°C steam conditions.
View Specifications
Industrial polarographic membrane design tracking ppb-level dissolved oxygen in ultrapure boiler feeds and high-temperature water analysis skids.
View Specifications
Smart microprocessor sensor outputting RS485 Modbus RTU directly to industrial telemetry edge controllers without supplementary transmitters.
View Specifications
Dual-channel multi-parameter controller simultaneously analyzing pure water electrical conductivity and pH with isolated 4-20mA current loops.
View SpecificationsIn modern industrial facilities, the continuous monitoring of electrical conductivity (EC) and its reciprocal, electrical resistivity (ρ), serves as the primary inline barrier against ionic contamination.
The microelectronics supply chain relies on UPW for cleaning silicon wafers after ion implantation, etching, and chemical mechanical planarization (CMP). Under the SEMI F63 standard, dissolved metallic cations (Na⁺, Ca²⁺, Fe³⁺) and anions (Cl⁻, SO₄²⁻) must be kept below parts-per-trillion (ppt) levels.
Any ionic ingress rapidly elevates conductivity above the theoretical baseline of 0.05501 μS/cm at 25.0°C (equivalent to 18.18 MΩ·cm resistivity). Our industrial electrodes feature mirror-polished titanium and 316L stainless geometries calibrated to k=0.0100 cm⁻¹ to ensure zero trace ionic shedding.
Purified Water (PW) and Water for Injection (WFI) regulated under USP <645>, EP, and ChP standards require non-temperature-compensated conductivity verification across a strict three-stage protocol.
Our online transmitters incorporate the exact three-stage USP <645> lookup matrix, dynamically calculating uncompensated conductivity against process temperature while alerting quality assurance operators prior to exceeding actionable validation ceilings.
Supercritical and ultra-supercritical thermal, combined-cycle, and nuclear turbines experience stress corrosion cracking when trace chloride or sulfate anions bypass polishers. SWAS requires measurement of Specific Conductivity (SC), Cation Conductivity (CC), and Degassed Cation Conductivity (DCC).
Our transmitters integrate ASTM D5391 acid/cation temperature compensation algorithms that calculate the precise ionization state of trace contaminants in high-purity steam condensates.
Next-generation proton exchange membrane (PEM) electrolyzers generate green hydrogen using ultrapure deionized water feedstocks. Even low-ppb levels of metallic ion contaminants cause irreversible degradation and membrane fouling, causing premature stack deactivation.
BOQU's industrial online conductivity meters provide real-time feed interlocks, ensuring that circulating water remains strictly below 0.1 μS/cm to maintain zero-carbon hydrogen production safety and high efficiency.
Why Standard Linear 2.0%/°C Temperature Compensation Fails Catastrophically in Pure and Ultrapure Water Loops
Unlike salt solutions where ion mobility dominates thermal conductivity shifts, ultrapure water is governed by the self-ionization constant ($K_w = [H^+][OH^-]$). At 0°C, pure water conductivity is approximately 0.011 μS/cm; at 25°C, it is 0.055 μS/cm; and at 100°C, it reaches 0.765 μS/cm.
Because this relationship is intensely exponential, applying standard linear compensation curves results in up to 30% measurement error, masking severe ionic contamination in pure water lines.
BOQU's smart conductivity transmitters decouple temperature coefficients into two discrete components according to ASTM D5391:
1. Pure Water Auto-Matrix: Applies the Light & Licht empirical dissociation equations to subtract the conductivity of pure water at the actual process temperature.
2. Solute Contaminant Matrix: Compensates residual salt or cation species (NaCl, HCl, NaOH, NH₄OH) with customized linear or power-law slopes back to the 25.0°C reference point.
This dual-channel algorithm guarantees that an operator looking at 0.055 μS/cm on a display is observing an accurate reading regardless of whether water is flowing at 15°C or 85°C.
Measuring conductivity below 0.1 μS/cm introduces severe vulnerability to external environmental factors:
| Parameter / Specification | BOQU Ultrapure Metrology Standard | Conventional Industrial Grade Meters | Technical Advantage |
|---|---|---|---|
| Measuring Range | 0.001 to 20.00 μS/cm (or 0.05 to 18.25 MΩ·cm) | 0.1 to 2000 μS/cm | Sub-nanosiemens resolution for critical reverse osmosis, EDI, and polishers |
| Cell Constant ($k$) | k = 0.0100 cm⁻¹ or k = 0.1000 cm⁻¹ (Certified) | k = 1.0 cm⁻¹ or k = 10.0 cm⁻¹ | Maximized electrode surface area and minimized cell gap for weak signal pickup |
| Wetted Materials | Titanium Grade 2 or 316L Stainless (Ra < 0.4 μm), PEEK | Graphite, Epoxylite, Standard 304 Stainless | Eliminates ion leaching, corrosion pitting, and microbial entrapment |
| Thermal Compensation | Non-linear ASTM D5391, ASTM D1125, USP <645> Table | Fixed linear 1.8% – 2.0% / °C | Prevents erroneous alarms caused by ambient thermal fluctuations |
| Digital Connectivity | Isolated RS485 Modbus RTU + Dual 4-20mA + HART | Unshielded Analog 4-20mA only | Immune to heavy VFD/pump inverter ground loops in plant environments |
Established in 2007 in Pudong, Shanghai, BOQU operates two specialized manufacturing centers encompassing 4,632 square meters of production space.
Unlike trading agencies, BOQU directly controls CNC machining of 316L and titanium electrode bodies. Our automated cleanrooms ensure vacuum glass sealing, micro-gap concentric alignment, and laser-welded temperature compensation junctions.
This vertical integration guarantees strict batch-to-batch repeatability and eliminates lead times for wholesale and customized ODM OEM specifications.
BOQU established a dedicated high-temperature water quality sensor testing laboratory in Kangqiao. Sensor designs undergo continuous thermal cycling from 0°C to 135°C to simulate steam sterilization (SIP) and high-temperature boiler returns.
Each sensor undergoes an intensive 48-hour continuous burn-in procedure before final quality release, preventing infant mortality in field deployments.
Our instruments conform to international electrical safety, EMC emissions, and industrial noise immunity requirements (EN 61326-1, EN 61010-1). Quality management is audited under ISO 9001 and environmental handling under ISO 14001.
Every conductivity cell is supplied with a factory calibration certificate showing traceable cell constant determination using NIST standard reference materials (SRM 3193).
From pre-treatment filtration to multi-stage polishing, BOQU provides end-to-end analytical configurations that protect critical processes from contamination.
Raw water is conditioned to remove particulate solids, organic load, and free chlorine prior to high-pressure reverse osmosis membranes.
In the deionization polishing loop, conductivity drops below 0.1 μS/cm. Process monitoring shifts to resistivity metrics (MΩ·cm).
Ultrapure water storage loops require continuous circulation to prevent stagnant microbial biofilm formation. Sanitization methods introduce aggressive conditions.
Direct technical answers from BOQU's instrumentation engineers and global support specialists.
The cell constant $k$ is the geometric ratio of the distance between measurement electrodes ($L$) to their effective cross-sectional area ($A$): $k = L / A$.
In ultrapure water where ion concentration is extremely low, electrical resistance ($R$) is high ($R = \rho \cdot k$). A high cell constant ($k=1.0$ or $10.0\text{ cm}^{-1}$) would generate resistances beyond the measurement capability of standard analog-to-digital converters, increasing susceptibility to electromagnetic noise. Using a certified cell constant of k = 0.0100 cm⁻¹ or k = 0.1000 cm⁻¹ reduces the measured resistance into an accurate range, providing stable sub-nanosiemens resolution.
USP <645> Water for Injection (WFI) regulations prohibit the use of temperature-compensated conductivity for Stage 1 validation. The process must read raw (uncompensated) conductivity alongside precise process temperature.
BOQU transmitters integrate the official USP <645> discrete Stage 1 lookup table in non-volatile firmware. If the fluid temperature is 25°C, the maximum allowed conductivity is 1.3 μS/cm; at 60°C, it is 2.2 μS/cm. The transmitter provides continuous verification and drives automated relay interlocks if the temperature-conductivity ceiling is approached, automating FDA/GMP compliance documentation.
Ultrapure water behaves as a chemical sponge for atmospheric gases. Air contains roughly 415 ppm of carbon dioxide ($CO_2$). When pure water is exposed to the atmosphere, $CO_2$ rapidly dissolves into the sample, forming carbonic acid ($H_2CO_3$), which dissociates into $H^+$ and $HCO_3^-$ ions.
This dissolution increases conductivity from theoretical purity ($0.055\ \mu\text{S/cm}$) to over $1.0\ \mu\text{S/cm}$ within seconds. Accurate ultrapure water measurements require gas-tight 316L stainless steel flow chambers with bottom-in, top-out sample flow to eliminate bubble accumulation and prevent air ingress.
Toroidal (electrodeless/inductive) sensors use magnetic coils to induce an electrical current in the fluid. They excel in harsh, fouling, and high-salinity media like CIP caustic lines or chemical neutralization tanks ($>500\ \mu\text{S/cm}$).
However, below $10\ \mu\text{S/cm}$, the induced current is too weak to detect accurately amidst magnetic hysteresis and core losses. Ultrapure water monitoring requires high-surface-area 2-electrode contact cells constructed from mirror-polished Titanium Grade 2 or 316L Stainless Steel with ultra-stable excitation frequencies to avoid sensor polarization.
Yes. Shanghai BOQU Instrument Co., Ltd. is an original equipment manufacturer with dedicated hardware, firmware, and mechanical engineering teams. We offer comprehensive wholesale OEM/ODM services, including private labeling, customized enclosure branding, modified insertion immersion lengths, proprietary cable assemblies, and custom communication firmware (Modbus RTU, BACnet, Profibus DP, or HART).
Explore BOQU's primary analytical instrumentation lineup. Every unit is manufactured under ISO 9001 quality systems and tested for 48 hours prior to dispatch.
Specialized S8 plug architecture with dual ceramic liquid junctions, ideal for rapid maintenance turnarounds in pharmaceutical pure water skids.
View Specifications
High-alkali low-sodium error glass formulation providing stable pH measurement during inline thermal sanitation routines up to 130°C.
View Specifications
Built-in precision temperature resistance element ensuring accurate compensation across variable-temperature process loops.
View Specifications
Sanitary sensor design engineered for biological synthesis, pilot plants, and ultra-pure water loop monitoring.
View Specifications
Engineered for extreme operating environments. Awarded Shanghai Brand distinction for stability and service life.
View Specifications
High-temperature dissolved oxygen electrode with fast response time and low drift in high-purity water and fermentation setups.
View Specifications
Intelligent RS485 communication sensor supporting direct connection to industrial IoT gateways and cloud monitoring architectures.
View Specifications
Dual-parameter controller monitoring conductivity and pH simultaneously on a single backlit graphical display panel.
View Specifications