ZDYG-2088-01QX Online Turbidity Sensor
Infrared 860nm scattered light optical sensor with mechanical wiper cleaning, delivering stable NTU/FTU and TSS telemetry under high fouling loads.
Explore ModelEngineered for immediate bulk procurement, system integrator white-labeling, and rigorous international municipal and bioprocess monitoring standards.
Infrared 860nm scattered light optical sensor with mechanical wiper cleaning, delivering stable NTU/FTU and TSS telemetry under high fouling loads.
Explore Model
Comprehensive modular monitoring array integrating low-range turbidity, free chlorine, pH, and conductivity for city water utility networks.
Explore Model
Industrial RS485 Modbus RTU telemetry directly from probe head; seamlessly networks beside turbidity systems for closed-loop dosing.
Explore Model
Shanghai Brand certified precision glass electrode engineered to endure repetitive CIP/SIP chemical thermal stress cycles up to 130°C.
Explore Model
Polarographic dissolved oxygen analyzer engineered for biopharma broth vessels, high-load aeration streams, and chemical process control.
Explore Model
Compact dual-input controller managing both physical turbidity/conductivity and ionic pH loops, ideal for space-restricted skid integration.
Explore Model
Heavy-duty IP65 industrial transmitter featuring dual 4–20 mA isolated current loops, RS485 telemetry, and solid-state limit relay switches.
Explore Model
Toroidal electrodeless sensor monitoring corrosive chemical concentrations and suspended matter without fouling or polarization degradation.
Explore ModelModern fluid handling infrastructure demands micro-NTU precision, robust solid-state optics, and self-diagnosing optical pathways to eliminate maintenance downtime.
Implementing 860 nm near-infrared (NIR) LED emitters paired with silicon photodiode arrays configured precisely at a 90° angle. This design eliminates liquid sample chromaticity interference and meets strict ISO 7027 and DIN EN 27027 industrial drinking water measurement criteria.
Contemporary digital optical assemblies integrate continuous drift compensation routines. Embedded microcontrollers track LED lumen degradation over time, calculate surface optical fouling indices, and dynamically prompt ultrasonic or mechanical wiping routines prior to data skewing.
Moving beyond lossy mV signaling, our wholesale turbidity sensors convert optical nephelometric data directly into high-baud Modbus RTU over RS-485 within the probe's encapsulated body, delivering industrial noise rejection across cable runs exceeding 500 meters.
Operating two dedicated production complexes across Kangqiao and Lingang, Shanghai, combining rapid prototyping with fully traceable mass-fabrication lines.
Unlike trading middlemen, BOQU operates its own precision CNC machining shops, automated SMT board placement bays, high-temp glassblowing facilities, and cleanrooms. This vertical integration reduces production lead times for wholesale orders to under 10 business days.
Every turbidity probe and online transmitter undergoes strict physical stress evaluation, continuous 48-hour thermal aging runs, and multi-point Formazin primary standard optical calibration prior to export crating, ensuring plug-and-play accuracy out of the shipping crate.
We provide complete customized hardware and software packages: custom form factors (immersion, flow-cell, in-pipe hot tap), private-labeled molded casing, customized RS485 communication protocols, extended high-temp cabling, and localized compliance certifications.
Ensuring tier-1 engineering compliance with regional water quality directives, regional telemetry protocols, and rapid technical escalation channels.
| Geographic Market | Core Compliance Standards | Typical Measurement Thresholds | Local Integration Ecosystem Support |
|---|---|---|---|
| European Union (EU) | CE, RoHS, WEEE, ISO 7027-1:2016, EN 61010-1 Electrical Safety | Drinking Water Directive: < 1.0 NTU at tap, < 0.2 NTU at filter plant outlet | Modbus RTU over RS-485, Profibus DP gateways, 4–20 mA NAMUR NE43 fault detection |
| North America (US / CA) | EPA Method 180.1, UL Listed Electronics Compatibility, FCC Part 15 Class A | EPA Surface Water Treatment Rule: ≤ 0.3 NTU in 95% of monthly filter readings | Integrated SCADA RTU integration, Allen-Bradley PLC register matching, NEMA 4X / IP68 enclosures |
| Asia-Pacific (APAC) | GB/T 5750, QCVN Class A (Vietnam), ISO 9001:2015, ISO 14001:2015 | Wastewater TSS discharge compliance: < 50 mg/L; Aquaculture DO > 5 mg/L | Multilingual firmware (English, Chinese, Vietnamese), direct 4G/5G MQTT IoT cloud gateways |
| Middle East & Africa | SASO Standards, CE Certification, High Ambient Heat Stability | Seawater RO desalination feed silt density (SDI) tracking & turbidity < 0.1 NTU | Extreme heat dissipation casings (-20°C to +65°C ambient), solar battery power compatibility |
Practical configuration guides tailored by BOQU application specialists to mitigate process abrasives, biological scaling, and ambient sunlight interference.
Low-range turbidity detection (0.001–10 NTU/FNU) downstream of rapid dual-media gravity filters. Utilizes localized low-volume bubble-trapping flow cells to prevent entrained micro-air bubbles from scattering light and triggering false filter breakthrough alarms.
High-range turbidity and Total Suspended Solids (TSS up to 50,000 mg/L) in biological aeration basins and secondary clarifiers. Fitted with pneumatic or mechanical silicon wiper systems to cycle every 30 minutes, preventing biofilm fouling on optical sapphire windows.
Real-time suspended solids telemetry across marine and freshwater RAS loops. Integrated with automated drum screen filter controllers to clear particulate waste, mitigating gill abrasion and preventing sudden nighttime dissolved oxygen collapses.
Turbidity-based optical density tracking in biomanufacturing downstream processing. Monitors centrifuge output and depth filtration trains to instantly detect cellular breakthrough during monoclonal antibody and vaccine purification sequences.
Match application operating ranges, media conditions, and mounting requirements to optimize instrument lifespan and project budgets.
| Model Series | Measuring Principle | Operating Range | Process Fitting | Wetted Materials | Best Suited Wholesale Applications |
|---|---|---|---|---|---|
| ZDYG-2088-01QX | 90° Infrared Scattered Light (860nm) | 0.01–400 NTU / 0–1000 NTU | Submersible / NPT 3/4" Thread | POM / 316L SS + Sapphire Glass | River stations, lake monitoring, clarifier effluent, general discharge |
| ZDYG-2088-02QX | Dual-Beam Attenuated Absorption | 0–20,000 mg/L (TSS) / 0–50,000 mg/L | Flange / Immersion Arm Installation | Titanium Alloy / SUS316L + FKM | Aeration tanks, sludge dewatering beds, dredge monitoring, mining slurry |
| MPG-6099-TB LowRange | Micro-Nephelometry with Degassing Cell | 0.001–10.00 NTU (Accuracy ±1%) | Flow-Through Bypass Manifold (6mm Tube) | Food-Grade Acrylic / PVDF | Municipal potable water networks, bottled beverages, membrane RO intake |
| IOT-TURB-485 Integrated | Solid-State Digital Backscatter | 0–4000 NTU (Auto-Ranging) | Drop-In / Pipeline Insertion | Corrosion-Resistant PPS Housing | OEM telemetry skids, smart agriculture, distributed solar-powered arrays |
Straight answers regarding MOQs, custom protocols, calibration standards, and distributor partnerships.
High-temperature electrochemical sensors, optical monitors, and trace chemical analyzers to complete your process telemetry setup.
Rugged autoclavable pH sensor engineered for sterile biopharma broths, resistant to repeated 130°C SIP steam sterilization cycles.
China High-temperature pH Sensor Used Pharmaceutical Fermentation Wholesaler, Supplier
Built-in Pt100/Pt1000 RTD temperature element delivering continuous automatic temperature compensation in harsh thermal reactions.
China High Temperature (0-130℃) pH Sensor With Temperature Wholesaler, Suppliers
Standardized PG13.5 mechanical thread with IP68 coaxial S8 connector, ensuring swift plug-and-lock maintenance replacement.
Wholesale High-temperature S8 Connector pH Sensor Manufacturers, Factory
Pressurized gel reference electrolyte prevents junction poisoning in high ionic strength solutions and hot chemical synthesis lines.
Wholesale High Temperature (0-130℃) pH Sensor Supplier, Factories
Constant-voltage amperometric system delivering real-time free chlorine data without expensive chemical buffer consumption.
Explore Model
Sub-ppb trace wet-chemical spectrophotometric analyzer engineered for high-pressure power plant steam and condensate circuits.
Explore Model
UV-persulfate oxidation method with NDIR detection, monitoring total organic carbon in pharmaceutical purified water loops.
Explore Model
Fully automated digestion and colorimetric station managing municipal and industrial wastewater compliance outfall telemetry.
Explore ModelWhether you require volume distribution pricing, private-label firmware development, or custom sensor design for specialized industrial processes, our Shanghai engineering team delivers complete technical recommendations within 24 hours.