Calibrated and pre-aged for 48 continuous hours in Shanghai testing facilities to ensure immediate out-of-the-box field deployment across worldwide utilities.
Steam-sterilizable glass formulation designed for harsh fermentation vessels and thermal industrial pipelines.
View Factory Specs
Specialized solid electrolyte barrier capable of withstanding repetitive CIP/SIP cycles without zero-point drift.
Wholesale Pricing
Extreme range electrochemistry engineered with pressurized reference junction for extreme reactor vessels.
Factory Datasheet
Dual-junction design embedded with PT100/PT1000 RTD for immediate Nernst equation thermal compensation.
Request B2B Quote
Certified Shanghai Brand sensor engineered specifically for biopharmaceutical bioreactors and ultra-sterile lines.
Review Engineering
Polarographic dissolved oxygen electrode built to endure autoclave sterilization while offering sub-ppb accuracy.
Explore Sensor
Direct RS485 Modbus RTU telemetry without external transmitters; integrates into SCADA and DCS architectures.
Request Volume Tier
Infrared 90-degree scattered light design featuring optional mechanical wiping blade for zero-maintenance operation.
Turbidity DatasheetTurbidity within the ultra-low and low range (0.000 to 20.00 NTU) serves as the primary operational litmus test for public health, chemical safety, and industrial yield management across international supply chains.
Global regulatory bodies including the US EPA (Method 180.1), European Drinking Water Directive (EU 2020/2184), and WHO Guidelines enforce finished water turbidity thresholds below 0.3 NTU (often targeting <0.1 NTU). Failure to maintain stable low-range readings correlates directly with Cryptosporidium and Giardia breakthrough risks.
In high-purity water architectures (Semiconductor FAB polishing loops and SWAS power plant feeds), suspended colloids below 5 NTU lead to premature fouling of costly Reverse Osmosis (RO) and Electrodeionization (EDI) membranes, turning routine filtration maintenance into severe CAPEX liabilities.
Tier-1 Western instrumentation brands typically exhibit 12-to-24-week delivery horizons and heavy price markups for low-range nephelometers. Municipal and EPC contractors increasingly pivot toward certified Tier-1 Chinese manufacturers capable of rapid scaling and integrated Modbus digital architectures.
Measuring turbidity below 20 NTU requires an absolute rejection of optical stray light, ambient bubble noise, and spectral temperature drift. Here is how BOQU solves the precision paradox.
| Core Dimension | ISO 7027 Standard (BOQU NIR Model) | US EPA 180.1 Standard (BOQU White Light Model) | Industrial Significance |
|---|---|---|---|
| Light Source Emitter | Infrared LED (860 nm ± 30 nm) | Tungsten Filament Lamp (2200K - 3000K) | IR completely eliminates sample color interference (true turbidity). |
| Detection Geometry | 90° Scattered Light Photodiode Array | 90° Nephelometric Detector with Forward Scatter Option | Optimized Mie scattering detection for microscopic colloidal particles. |
| Resolution (0-20 NTU) | 0.001 NTU (Dynamic Averaging Engine) | 0.001 NTU (High Sensitivity Photomultiplier) | Guarantees pinpoint drift detection at 0.05 NTU regulatory setpoints. |
| Degassing Mechanism | Integrated Cyclone Bubble Trap Column | Flow-through Pressurized De-bubbling Vessel | Purges micro-bubbles that mimic false suspended particulate peaks. |
| Signal Telemetry | RS485 Modbus RTU / 4-20mA Galvanic Isolated | HART Protocol / Dual Solid-State Relays | Direct industrial network pairing without costly auxiliary gateways. |
Engineered with black-anodized internal light sinks and sapphire optical windows that diminish stray light reflections to <0.01 NTU, critical for true ultra-trace baseline accuracy.
Microcontroller-level real-time compensation algorithms dynamically correct for LED thermal decay over 50,000 continuous hours, extending routine calibration intervals from weeks to months.
Optional continuous ultrasonic vibration transducers prevent biological film crystallization and lime adhesion on sensor optical faces without interfering with 90-degree photodetectors.
From municipal secondary distribution networks to pharmaceutical batch fermenters, our 0-20 NTU instrumentation suite is calibrated to specific process chemistries and flow dynamics.
Direct placement on dual-media rapid sand and GAC filter effluent headers. Detects media breakthrough and flocculation collapse in real time to prevent unchlorinated pathogen bypass into municipal reservoirs.
Sanitary flow-cell installations validating ultra-pure water loops following reverse osmosis and distillation. Ensures absolute clarity prior to formulation vessels and batch bioprocess fermenters.
Integration into Steam and Water Analysis Systems (SWAS) to monitor trace iron oxide (crud) transport into supercritical boiler loops, preventing costly turbine blade deposition and localized thermal corrosion.
Automated diatomaceous earth and membrane filtration control in breweries and beverage bottling. Immediate feedback controls dosing of fining agents, guaranteeing bright clarity without manual lab titration.
Continuous monitoring of post-CMP wafer rinsing loops where even single sub-micron colloidal particles induce bridge defects in sub-7nm node silicon production lines.
Continuous SDI and turbidity profiling on seawater intakes following dissolved air flotation (DAF) and ultrafiltration, safeguarding spirally-wound polyamide high-pressure SWRO modules.
True manufacturing ownership eliminates trader markups and guarantees rapid delivery cycles. Discover the infrastructure backing our 0-20 NTU analytical instrumentation line.
Operating across 4,632 square meters in Kangqiao Industrial Zone and Lingang High-Tech Area. Housing dedicated cleanrooms for optical prism polishing, SMT automated surface-mount PCB lines, and robotic sensor encapsulation bays.
Pioneers of China's premier high-temperature electrochemical and optical calibration testbeds. Every optical receiver undergoes precision multi-point laser alignment, ensuring zero cross-axis scattering artifact distortion.
Zero dead-on-arrival (DOA) tolerance. 100% of finished turbidity transmitters, digital sensors, and flow assemblies endure dynamic thermal chamber cycles and uninterrupted 48-hour continuous data verification before export packaging.
While European manufacturers quote 8 to 16 weeks, our direct supply chain and standard component inventory facilitate dispatch in 3 to 7 business days for standard models, and under 20 business days for complete custom OEM container loads.
From private-label housing silkscreening, customized GUI menu layouts in 7 languages, to tailored firmware Modbus register mapping matching your legacy PLC hardware, our R&D team implements custom modifications at zero extra engineering fee for volume buyers.
Delivered with individual calibration certificates traceable to primary Formazin stock formulations according to ISO 7027 and EPA specifications, satisfying all ISO/IEC 17025 municipal laboratory auditing conditions.
Gain total cost clarity. Our tiered pricing structure empowers system integrators, EPC engineering contractors, and regional distributors to protect commercial project margins.
| Model / Configuration Tier | Key Technical Specifications | Sample Tier (1-4 Units) | Tier 1 (5-19 Units) | Tier 2 (20-49 Units) | Wholesale Container (50+ Units) |
|---|---|---|---|---|---|
| BOQU TB-020-Pro Low-Range Nephelometer (Panel System) | 0.000 - 20.00 NTU, Bubble Trap, 90° ISO 7027, 4-20mA + RS485, LCD Controller | $850 - $1,100 | $680 - $790 | $540 - $630 | Direct Factory Consultation |
| ZDYG-2088-01QX Digital Smart Sensor (Standalone) | Submersible or Inline, RS485 Modbus Direct, Auto-wiper option, IP68 Stainless 316L | $480 - $650 | $380 - $460 | $290 - $350 | Direct Factory Consultation |
| TB-EPA-180 White Light Analyzer (EPA Compliant) | Tungsten Lamp, 0-20 NTU, Micro-Flow Cell, Regulatory EPA 180.1 reporting format | $950 - $1,250 | $780 - $890 | $620 - $710 | Direct Factory Consultation |
| MPG-6099Plus Multi-Parameter Panel (Integrated) | Turbidity (0-20 NTU) + Residual Chlorine + pH + Conductivity, Turnkey Backplate | $1,800 - $2,400 | $1,450 - $1,680 | $1,200 - $1,380 | Direct Factory Consultation |
By implementing ultra-durable solid-state NIR LEDs with a 50,000-hour MTBF, BOQU analyzers eliminate expensive annual lamp replacement routines common in legacy incandescent analyzers.
Unlike Western competitors that force operators to purchase costly proprietary calibration pouches, our open-calibration firmware allows calibration using standard generic Formazin or AMCO-Clear suspensions.
All mechanical wiping seals, quartz optical chambers, O-rings, and replacement circuit modules are guaranteed available in stock with immediate worldwide dispatch within 24 hours.
Deploying instrumentation into regulated utilities demands verifiable quality management, strict electromagnetic compliance, and robust technical documentation.
Certified under ISO 9001:2015 for design and manufacturing, ISO 14001 for environmental management, with full CE compliance for electromagnetic immunity (EN 61326-1) and low voltage directives. FDA-compliant wetted materials certificates available on request.
Our instruments support 1-to-5-point progressive calibration workflows. Operators can calibrate using StablCal or freshly synthesized Formazin primary standards at 0.5 NTU, 5.0 NTU, and 20.0 NTU with intuitive automatic slope calculation.
Direct factory application engineers provide real-time remote commissioning, Modbus register diagnostics, and SCADA integration assistance via dedicated video sessions, reducing on-site engineering troubleshooting times.
Clear, technically detailed answers regarding precision, installation, maintenance, and factory commercial terms.
The difference lies in spectral physics. ISO 7027 requires an infrared 860 nm LED light source, making it immune to sample color (such as humic acids in raw water) and eliminating sample thermal absorption. US EPA Method 180.1 mandates a tungsten filament lamp emitting white light (400-680 nm), which provides superior scattering sensitivity on sub-micron colloidal particles but is susceptible to color interference. BOQU manufactures factory configurations compliant with both standards.
Entrained micro-bubbles act like suspended solids, scattering light at 90 degrees and causing false turbidity spikes. BOQU 0-20 NTU systems utilize a specialized vortex bubble-trap column before the measurement chamber. By decelerating fluid velocity and creating a controlled cyclonic upward flow, micro-bubbles coalesce and escape through an atmospheric vent while de-aerated laminar sample water enters the optical measurement chamber.
BOQU is a 100% direct manufacturer established in Shanghai in 2007. We operate two production campuses in Kangqiao and Lingang covering 4,632 square meters, employing over 200 skilled staff, including an internal R&D team of 35 optoelectronic and software engineers. We produce over 100,000 instruments annually. Overseas clients are invited to inspect our facilities via 360-degree VR or on-site factory audits.
Yes. Our IOT-485 digital series sensors feature internal microprocessors that perform analog-to-digital signal conversion, temperature compensation, and calibration calculations directly inside the sensor body. They output standardized RS485 Modbus RTU protocol, allowing direct integration into your PLC, DCS, RTU, or IoT cellular telemetry units without purchasing a wall-mounted controller.
In municipal potable water applications running between 0.05 and 1.0 NTU, we recommend a secondary standard verification check once a month using certified AMCO-Clear sealed standards, and a full primary Formazin calibration every 3 to 6 months. Thanks to our ultra-stable solid-state LED emitters, zero drift is less than 0.01 NTU per month under normal operating conditions.
For standard BOQU branded units, the MOQ is just 1 unit. For custom OEM branding (custom silkscreen logo on sensor housing and display, custom model naming in firmware, and localized instruction manuals), our typical threshold begins at 10 units. Standard orders dispatch in 3 to 7 business days, while customized OEM runs are completed in 15 to 20 business days.
Pair low-range turbidity meters with multi-parameter analysis controllers to achieve fully automated closed-loop treatment and regulatory reporting across municipal and industrial assets.
Dual-channel continuous monitoring of pH and electrical conductivity on a single display; ideal for RO and hydroponics.
View Specifications
Combines low-range turbidity, free chlorine, pH, and conductivity onto a single pre-plumbed, wall-mounted backplate.
Request System Details
Heavy-duty aluminum IP65 housing offering isolated 4-20mA and dual SPDT alarm relays for neutralizing dosing circuits.
Review Engineering
Inductive toroidal conductivity technology for acid, caustic, and chemical CIP concentration validation without electrode fouling.
Wholesale Pricing
Continuous amperometric measurement for drinking water disinfection validation; pairs with 0-20 NTU turbidity alarms.
View Chlorine Specs
Sub-ppb photometric trace silica, phosphate, and sodium determination protecting high-pressure steam turbines.
Explore SWAS Unit
UV-persulfate oxidation with NDIR detection for pharmaceutical WFI systems and microelectronics organic carbon screening.
Request B2B Quote
Automated micro-wet digestion colorimetry delivering continuous municipal and industrial environmental discharge compliance.
Factory DatasheetConnect directly with senior optical and water quality engineers at our Shanghai Kangqiao headquarters. We provide complete tender documentation, customized Modbus register configuration, and volume container pricing.