High Temperature (0-130℃) pH Sensor
Equipped with solid-state polymeric electrolyte and porous annular PTFE junction for extreme chemical streams.
View Factory SpecsFactory-direct instruments certified under ISO 9001 and CE frameworks. Each inline probe undergoes rigorous 48-hour pressure-thermal aging and multi-point calibration prior to international dispatch.
Equipped with solid-state polymeric electrolyte and porous annular PTFE junction for extreme chemical streams.
View Factory Specs
Embedded Pt100/Pt1000 RTD element providing dynamic Nernst slope correction across boiling industrial solutions.
View Factory Specs
Standard PG13.5 mechanical thread with IP68 coaxial S8 connection suitable for automated insertion fittings.
View Factory Specs
Certified non-cytotoxic gel, withstands SIP/CIP cycles with zero drift in high-density bacterial bioreactors.
View Factory Specs
Shanghai Brand recipient, designed specifically for extreme thermal cycling in pressurized steam applications.
View Factory Specs
Polarographic dissolved oxygen transducer featuring stainless steel 316L body and autoclavable silicone membrane.
View Factory Specs
Direct-bus connection probe outputting calibrated Modbus RTU metrics, eliminating expensive standalone transmitters.
View Factory Specs
Compact dual-channel controller calculating TDS, salinity, and conductivity while operating dynamic dosing relays.
View Factory SpecsTotal Dissolved Solids (TDS) sensors serve as critical gatekeepers across automated water conditioning infrastructure. Understanding the physical principles and global supply chain dynamics allows procurement engineers to balance capital expenditure with drift-free operational longevity.
The global demand for high-reliability TDS sensors is accelerating at an estimated 7.8% CAGR, spurred by strict zero-liquid-discharge (ZLD) directives in municipal water treatment, semiconductor ultra-pure rinse water fabrication, and large-scale seawater reverse osmosis (SWRO) facilities across APAC, the EMEA zone, and the Americas.
Industrial "Sensor de TDS" instrumentation fundamentally tracks Electrical Conductivity (EC in µS/cm or mS/cm) and applies a mathematical conversion coefficient ($k_e$). BOQU manufacturing integrates software-switchable conversion factors ($k_e = 0.50$ to $0.70$) according to standard salt references (NaCl, 442, or KCl), preventing cross-regional analytical deviation.
Direct Tier-1 factory integration eliminates distributor margins while guaranteeing batch-to-batch electrode cell constant accuracy ($K = 0.01, 0.1, 1.0, 10.0$). Standardized wholesale orders secure turnkey compliance packages including traceable NIST certification sheets, third-party SGS metallurgical audits, and customized firmware registers.
Indicative commercial pricing for system integrators, EPC engineering contractors, and water treatment distributors. High-volume custom OEM batches are discounted based on annual delivery schedules.
| Model / Sensor Series | Sensor Architecture | Operating Range & Temp | Ingress / Process Fitting | Typical Volume Price (USD) | Target Applications |
|---|---|---|---|---|---|
| TDS-Compact 100 | 2-Electrode Stainless Steel 316L (K=0.1) | 0.05 – 200 ppm (0 – 80℃) | IP68, 1/2" NPT Male Thread | $38.00 – $65.00 | RO Pure Water, Commercial Boilers, Potable Lines |
| TDS-Inductive 500 | Toroidal / Electrodeless PEEK Core | 10 – 100,000 ppm (0 – 130℃) | IP68, 1.5" Sanitary Clamp / Tri-Clamp | $195.00 – $320.00 | Heavy Wastewater, CIP Caustic Lines, Desalination |
| TDS-HighTemp Pro (pH5806 Series) | Platinum / Polymeric Junction Glass | 0 – 20,000 ppm (0 – 130℃) | PG13.5 Quick S8 Socket Thread | $85.00 – $140.00 | Sterile Fermentation, Thermal Chemical Processing |
| IOT-Digital 485-TDS | 4-Electrode Graphite Anti-Polarization | 0.1 – 50,000 ppm (-10 – 90℃) | IP68 Submersible, 3/4" NPT Thread | $110.00 – $185.00 | IoT Smart Agriculture, River Catchment, RAS Fish Farms |
| DCA-Combo Transmitter Suite | Dual-Channel Controller + Probe Assembly | Programmable TDS/EC/pH Modules | NEMA 4X / IP65 Panel Enclosure | $240.00 – $410.00 | Complete Industrial Skid Automation, Dosing Skids |
* FOB Shanghai pricing. Tier pricing applies to 50+ unit MOQs. Detailed quotations reflect cable extensions and custom sensor metallurgy.
The evolution of sensor de TDS systems hinges on digital integration, fouling resistance, and low-latency feedback algorithms capable of interfacing directly with cloud microservices and plant DCS infrastructures.
Traditional millivolt analog loops suffer signal degradation across extensive plant cabling. The modern BOQU roadmap shifts toward embedded 32-bit DSP microprocessors directly within the sensor cap, running on-board fast Fourier transform (FFT) noise-filtering before streaming RS485 Modbus packets.
Electrode surface contamination causes false-low TDS readings. Integrating dynamic impedance analysis enables our controllers to differentiate between genuine mineral reductions and biofilm build-up, notifying control operators of cleaning schedules before process compliance fails.
For chemical and heavy wastewater applications, electrodeless toroidal transformers encapsulated in chemical-grade PEEK eliminate polarization error entirely, permitting maintenance-free continuous analysis in aggressive electrolytic streams.
Modular SCADA interfaces facilitate turnkey synchronization across variable frequency drive (VFD) booster pumps, automated RO membrane backwash sequencing, and chemical metering injection pumps to guarantee strict discharge effluent standards.
How BOQU instrumentation maintains precision inside rigorous operating environments worldwide.
Microbial cultures synthesize high-value active pharmaceutical ingredients (APIs) only within narrow ionic profiles. In installations spanning India and Eastern Europe, BOQU high-temperature sterilizable sensors endure live 130℃ steam SIP sterilization without recalibration or electrolyte exhaustion.
At regional water treatment skids in Southeast Asia and the Middle East, online TDS dual-channel transmitters maintain constant recovery ratio checks before and after reverse osmosis membranes, instantly detecting seal failure or salt passage breakthroughs.
High-pressure steam turbines are vulnerable to mineral scaling from dissolved silica and sodium. In municipal waste-to-energy power facilities across China, BOQU SWAS sub-assemblies continuously track cation conductivity and micro-level TDS at parts-per-billion sensitivity.
Crucial insights for system integrators, plant managers, and international procurement specialists.
Explore multi-parameter wall mounts, optical turbidity elements, and wet-chemical compliance analyzers built for round-the-clock plant uptime.
860nm ISO 7027 infrared scattered light probe with optional integrated mechanical wiper for sludge and effluent monitoring.
View Factory Specs
Skid-mounted panel analyzing pH, TDS, residual chlorine, and turbidity for secondary water supply networks.
View Factory Specs
IP65 housing, dual isolated 4-20mA loop outputs, high/low limit relays, and RS485 Modbus RTU communications.
View Factory Specs
Toroidal inductive meter tracking HNO3, H2SO4, HCl, and NaOH solution percentages in chemical regeneration lines.
View Factory Specs
Amperometric constant-voltage sensor measuring free chlorine and chlorine dioxide without chemical reagent consumption.
View Factory Specs
Ultra-trace optical colorimetry monitoring parts-per-billion contaminants across high-pressure boiler feed steam loops.
View Factory Specs
Catalytic UV oxidation method compliant with USP <643> and EP 2.2.44 for pharmaceutical-grade purified water loops.
View Factory Specs
Automated wet-chemical digestion platform verifying regulatory compliance with automatic cleaning and calibration.
View Factory Specs