Wholesale Sensor Chlorine Supplier & Pricelist

Engineered Industrial-Grade Chlorine Sensing Arrays, Direct Factory OEM/ODM Sourcing, Tiered Volume Economics, and International Water Quality Compliance.

Factory-Direct Instrumentation

High-Precision Inline Analytical Sensors & Transmitters

Verified instrumentation manufactured in our ISO 9001:2015 accredited Shanghai laboratories, configured for harsh chemical disinfection loops and high-temperature thermal cycling.

Industrial Specification Whitepaper

Analytical Residual Chlorine Sensing: Physics, Chemistry & Scale Procurement

Understanding total electrochemical kinetic control, constant-voltage amperometry, and the critical distinction between Free Available Chlorine (FAC) and Total Combined Chlorine in municipal and industrial networks.

Amperometric Constant-Voltage Physics

Unlike passive colorimetric DPD instruments requiring ongoing chemical reagents, our bare gold/platinum electrode assemblies maintain a dynamic polarization voltage, directly reducing hypochlorous acid (HOCl) to chloride ions to establish real-time micro-ampere proportional current feedback with sub-second response times.

Dynamic pH & Thermal Compensation

Disinfection efficacy fundamentally hinges on the HOCl / OCl⁻ dissociation equilibrium curve. Our integrated algorithms utilize embedded dual PT1000 sensors paired with precision pH electrodes to compensate mathematical dissociation shifts across pH 5.5 to 9.5 and temperatures from 0 to 50°C automatically.

Direct Modbus RTU & Industrial IoT

Eliminate costly standalone signal convertors. Every modern BOQU digital chlorine sensor embeds isolated RS485 Modbus RTU micro-controllers right into the waterproof IP68 enclosure, communicating operational metrics, calibration slopes, zero offsets, and predictive diagnostics directly to SCADA and DCS.

Factory-Direct Economics

2026 Wholesale Residual Chlorine Sensor Sourcing Pricelist

Contract manufacturing tiers, OEM framework agreements, and system integrator volume discounts. All quotes FOB Shanghai or CIF Global Sea/Air Ports.

Model Series Measurement Type Detection Range Digital Outputs MOQ Tiered Wholesale FOB Range
CL-2088S Digital Amperometric Free Chlorine (HOCl / OCl⁻) 0.00 to 20.00 mg/L (ppm) RS485 Modbus RTU, 4-20mA 10 Units $180 – $240 / Unit
CL-2088-HP Industrial Membrane Free & Total Combined Chlorine 0.005 to 10.00 mg/L Isolated Dual 4-20mA, Relays 5 Units $280 – $360 / Unit
MPG-6099CL Wall Skid Panel Multi: Free Cl + pH + Temp + Flow 0.00 to 10.00 mg/L / 0-14 pH Modbus, Relays, Cloud MQTT 2 Sets $750 – $980 / Set
BYS-Chlorine-OEM Cartridge Bare Gold Amperometric Cell 0.01 to 5.00 mg/L Raw mV / μA Analog Pre-Amp 50 Units $65 – $95 / Unit
CL-485-Mini Inline Submersible Direct Stream Chlorine Sensor 0.01 to 20.00 ppm Modbus RTU Direct (3.3V/5V DC) 20 Units $140 – $190 / Unit

*Pricelist based on raw material batch standards. Custom ODM telemetry, branded molding, and extended subsea cable runs calculated per application specification.

End-to-End Vertical Integration

China Factory Supply Chain Infrastructure & Technical Capabilities

Headquartered in Shanghai, BOQU operates 4,632 m² of specialized production space across two state-of-the-art facilities in Kangqiao and Lingang, producing over 100,000 instruments annually.

Electrode Micro-Fabrication

We maintain full ownership of precision electrochemical core processing, from platinum micro-welding and high-vacuum glass blowing to constant-impedance reference junctions, ensuring 100% batch traceability.

Automated 48-Hour Burn-In

Every single sensor and analyzer module undergoes stringent 48-hour continuous thermal cycling, dielectric insulation tests, and electrochemical drift aging before entering our automated calibration verification rigs.

Comprehensive OEM & ODM

From custom CNC housing geometries (PVDF, Titanium, PEEK, 316L Stainless Steel) to private-labeled firmware boot screens and custom baud-rate Modbus registers, we engineer bespoke sensor lines for global brand catalogs.

Unbroken Component Logistics

Located in the heart of the Shanghai Pudong industrial belt, our supply pipeline features uninhibited raw material access, dampening global transit shocks and guaranteeing 1-to-2 week dispatch on volume wholesale orders.

2007
Established in Shanghai
4,632 m²
High-Tech Production Facilities
100,000+
Annual Instrument Yield
100+
Countries Globally Supplied
Compliance & Reliability

International Regulatory Compliance & Local Engineering Support

Procuring analytical chlorine sensor skids across borders demands uncompromising conformance with local health codes, water authority validation protocols, and industrial functional safety parameters.

Drinking Water Safety Protocols

Our chlorine analyzers comply with WHO potable water guidelines (mandating ≥0.5 mg/L free chlorine after 30-minute contact time at pH <8.0), US EPA Method 334.0 validation protocols for continuous chlorine monitoring, and European EN 17093 drinking water disinfection regulations.

Certified Production Framework

Instruments operate under ISO 9001 (Quality Management) and ISO 14001 (Environmental Standards). Electronics hold complete CE electromagnetic compatibility (EMC) declarations, SGS third-party facility verification, and FDA food-grade compliance on fluid wetted components.

Local Commissioning Partnerships

Backed by trained field service partners across Southeast Asia, the Middle East, Europe, and the Americas, wholesale clients receive comprehensive schematic drawings, zero/span calibration standard buffer sets, and English-speaking tier-3 engineering escalation hotlines.

Target Industrial Use Cases

Mission-Critical Operational Deployment Scenarios

Engineered for mission-critical installations requiring zero unplanned process downtime, non-stop chemical feedback, and automated dosing interlock triggers.

Municipal Drinking Water & Networks

Continuous monitoring at raw intake chlorination points, sand filter backwash effluent loops, and secondary high-rise booster pumping reservoirs to guarantee bacteriological safety without generating noxious trihalomethane (THM) byproducts.

Industrial Cooling Tower Biocides

Regulating hypochlorite and chlorine dioxide injection in heavy power plant and petrochemical open recirculating cooling systems. Eliminates aggressive Legionella colonization while preventing excessive piping corrosion through precise millivolt relay interlocks.

Wastewater Final Disinfection (Dechlorination)

Municipal wastewater plants discharging into sensitive marine or river habitats require fast-acting chlorine sensors to govern final sodium bisulfite dechlorination feed, ensuring residual effluent chlorine stays strictly beneath <0.02 ppm environmental limits.

Commercial Aquatics & Theme Parks

High-bather-load aquatic centers rely on our dual chlorine/pH flow cells to instantly compensate for urea-induced chloramine spikes, maintaining crystal clear sanitation balance while stopping eye and dermal irritation instantly.

Food & Beverage Produce Wash Lines

Post-harvest agricultural washing and poultry processing lines deploy our bare-gold electrode units in high-turbidity conditions, continuously pacing chlorine chemical sanitizer injection to neutralize pathogens without halting processing conveyor speeds.

Reverse Osmosis (RO) Membrane Protection

Thin Film Composite (TFC) polyamide RO membranes degrade permanently if exposed to trace free chlorine. BOQU ultra-trace amperometric sensors offer sub-ppb sensitivity upstream of membrane stages to trigger auto-dump emergency valves reliably.

Future Industry Trajectory

Emerging Trends Reshaping the Chlorine Sensing Industry

The global residual chlorine instrumentation landscape is transitioning rapidly from labor-heavy manual chemical sampling toward self-maintaining, reagentless edge-computing topologies.

Automated In-Situ Hydrodynamic Cleaning

Conventional membrane fouling and electrode polarization require routine service calls. The future belongs to dynamic motorized cleaning spheres and ultrasound pulses integrated straight into flow cells, maintaining immaculate electrochemical interfaces for 6+ months untouched.

Predictive Sensor Health Algorithms

Modern BOQU chlorine transmitters don't just broadcast chemical parts-per-million; they actively measure electrode electrochemical impedance spectroscopy (EIS) parameters, alerting plant control engineers weeks before electrolyte exhaustion or reference degradation induces drift.

Zero-Reagent ESG Sustainability

Global environmental mandates are aggressively phasing out DPD (N,N-diethyl-p-phenylenediamine) reagents due to ongoing toxic chemical waste production and disposal compliance costs. Reagentless amperometric constant-voltage hardware represents the sole green path forward.

Procurement & Technical FAQ

Frequently Asked Questions for Wholesale Chlorine Sensor Buyers

Get immediate, transparent technical answers to expedite your procurement evaluations and system integrations.

What is the principal operational difference between bare-electrode and membrane-covered amperometric chlorine sensors?
Bare-electrode constant-voltage chlorine sensors utilize exposed noble metal (Gold or Platinum) pins directly touching the process water, which eliminates the recurring cost of replacing delicate polymer membranes and gel electrolytes. They rely on constant hydrodynamic flow velocity or hydrodynamic mechanical scrubbing beads to prevent polarization. Membrane-covered sensors pass chlorine through a microporous gas-permeable PTFE membrane into an internal electrolyte buffer, isolating the cathode from ionic interference and surfactants, making them ideal for complex, oily, or variable conductivity wastewater streams.
Why is integrated pH compensation essential for accurate free chlorine measurement?
When chlorine gas or hypochlorite dissolves in water, it forms Hypochlorous Acid (HOCl) and Hypochlorite Ions (OCl⁻). Amperometric sensors directly measure only the electrically neutral HOCl molecule, which has up to 80-100 times stronger biocidal efficacy than OCl⁻. However, as process water pH rises from 6.5 to 8.5, HOCl dissociates rapidly into OCl⁻. Without simultaneous inline pH sensing and dynamic micro-algorithmic calculation, a standard chlorine sensor will mistakenly report a massive drop in free chlorine even when total chemical disinfectant concentration remains identical.
What are the lead times, MOQ requirements, and shipping capabilities for international container orders?
Standard OEM/ODM production batches have a low baseline Minimum Order Quantity (typically 5 to 10 units for complete transmitter systems and 20 to 50 units for replacement electrochemical cartridges). Standard models dispatch within 3 to 7 business days from our Shanghai warehouse. Custom engineering orders (special communication registers, proprietary branded housings, or multi-parameter skid panels) typically ship within 14 to 21 business days via DHL, FedEx, or consolidated sea freight.
Can BOQU chlorine sensors integrate seamlessly into existing third-party PLC and SCADA platforms?
Yes. Every sensor module and controller supports standardized industrial communication protocols. Our digital IoT sensors output direct RS485 Modbus RTU (standard 9600 baud, 8-N-1), enabling direct daisy-chain connection to Siemens, Allen-Bradley, Schneider Electric, or Mitsubishi PLCs without needing auxiliary signal converters. Additionally, our wall-mounted controllers feature isolated 4-20mA analog loops and programmable SPDT mechanical relays for direct dosing pump pacing.
What calibration routine and maintenance schedule are recommended for long-term field stability?
Amperometric sensors require an initial zero-point check (using chlorine-free dechlorinated water or activated carbon filtered water) followed by a slope span calibration using a validated DPD photometer or portable colorimeter test kit. In standard municipal potable water, calibration drift is typically less than 2% per month, requiring span recalibration once every 30 to 60 days. Membrane modules and internal electrolytes generally require inspection and renewal once every 6 to 12 months, depending on organic fouling loads.
Factory Equipment Portfolio

High-Reliability Water Analysis Portfolio

Explore our comprehensive industrial catalog of high-temperature pH, dissolved oxygen, turbidity, and chemical disinfectant sensors ready for global enterprise distribution.