Online Residual Chlorine Analyzer
Continuous free chlorine monitoring for drinking water networks, industrial cooling, and chlorine dosing control loops.
View Specifications →Direct factory wholesale configurations manufactured under ISO 9001 quality systems with strict 48-hour continuous drift and stability calibration runs.
Continuous free chlorine monitoring for drinking water networks, industrial cooling, and chlorine dosing control loops.
View Specifications →
Consolidated flow-cell station combining residual chlorine, pH, turbidity, conductivity, and dissolved oxygen.
View Specifications →
Awarded Shanghai Brand certification; engineered for high-temperature biopharma fermentation and SIP cycles.
View Specifications →
Direct RS485 Modbus RTU communication designed for edge gateways and DCS integration without secondary transmitters.
View Specifications →
Integrated temperature compensation electrode, fully resilient against repetitive steam sterilization up to 130°C.
View Specifications →
Optimized reference electrolyte matrix preventing poisonous fouling in thick microbiological broths and reactors.
View Specifications →
Infrared 860nm scattered light sensor complete with ultrasonic self-cleaning options for water distribution networks.
View Specifications →
Dual-channel transmitter managing real-time chlorine disinfection dosing synergy alongside pH and conductivity.
View Specifications →Understanding the core physics and electrochemistry of Hypochlorous Acid (HOCl) and Hypochlorite Ion (OCl⁻) detection is critical for wholesale buyers and plant instrument engineers.
Utilizes a selective microporous gas-permeable PTFE membrane isolating a gold working cathode and silver anode in an internal electrolyte. Hypochlorous acid diffuses across the boundary layer, producing a direct reduction current:
HOCl + 2e⁻ + H⁺ → Cl⁻ + H₂O.
Offers high specificity in industrial wash lines where ionic surfactants would foul open electrodes.
Employs a 3-electrode potentiostatic system (Working, Counter, Reference) without disposable membranes or consumable chemicals. Integrated auto-cleaning impellers or hydrodynamic sand scrubbing prevent biological film accumulation on the platinum surfaces, drastically reducing OpEx in municipal tap water grids.
Follows Standard Methods 4500-Cl G using N,N-diethyl-p-phenylenediamine reagent buffers. Periodic photometric light absorption measurement (510–550 nm) delivers calibration-free reliability for regulatory reporting compliance, irrespective of water conductivity swings or fluctuating pH conditions up to pH 8.5.
| Technology Class | pH Dependency & Compensation | Maintenance Interval | Interference Profile | Optimal Deployment Arena |
|---|---|---|---|---|
| Potentiostatic Bare Amperometric | Dynamic software algorithm required (pH 5.5 - 8.2) | 3 - 6 Months (Mechanical self-clean) | Low sensitivity to turbidity; prone to Cu²⁺, Fe³⁺ | Secondary municipal booster stations & cooling towers |
| Membrane Polarographic Probe | Requires narrow pH buffer or dual pH/temp input | 1 - 2 Months (Membrane/Electrolyte replacement) | Protected against dissolved metals; fouled by fats/oils | Pure drinking water networks & industrial effluent loops |
| DPD Photometric Wet Chemistry | Independent (Reagent buffers sample to pH 6.3 - 6.6) | 30 Days (Reagent replenish & peristaltic tube check) | High turbidity causes scattering; oxidized manganese | EPA / WHO regulatory compliance outfalls & plant inlets |
Residual chlorine monitors operate under widely disparate water matrix conditions across varying regional guidelines and process extremes.
Compliant with WHO guidance (holding residual free chlorine ≥0.5 mg/L after 30 mins contact at pH <8.0). Prevents pathogen regrowth across lengthy distribution pipe networks while avoiding trihalomethane (THM) disinfection byproducts.
Automates the slug-dosing of sodium hypochlorite or chlorine dioxide to eliminate Legionella pneumophila while limiting excessive oxidant levels that cause accelerated microbially-induced corrosion (MIC) on copper chiller tubing.
Thin-film composite (TFC) polyamide Reverse Osmosis membranes degrade rapidly when exposed to >0.1 ppm free chlorine. In-line amperometric monitors verify complete sodium metabisulfite (SMBS) dechlorination before feed water enters expensive RO vessels.
Maintains tight synergy between free available chlorine and combined chlorine (chloramines). Coupled with pH transmitters, systems eliminate mucous membrane irritation and eye burn for bathers while ensuring bacteriological compliance.
Leveraging two fully certified facilities in Kangqiao and Lingang, Shanghai Boqu Instrument Co., Ltd. eliminates middleman costs with vertical integration spanning PCB layout, glassblowing, and multi-gas injection.
All analog-to-digital converters, potentiostatic conditioning chips, and quartz flow-cell manifolds are source-verified. Complete assembly takes place on automated SMT lines with 100% optical inspection.
Every manufactured residual chlorine monitor and high-temperature probe undergoes a compulsory 48-hour continuous thermal and electronic aging chamber test to eradicate infantile component failure before global export.
Full firmware and hardware customization: private-labeled front panels, custom Modbus register addresses, broad-spectrum power configurations (24VDC, 110VAC, 220VAC), and customized flow-cell mechanics.
Engineered to comply with stringent water safety frameworks globally including US EPA Method 334.0, European EN 61010-1 electrical norms, and ISO 14001 manufacturing standards.
Designed for native PLC and DCS integration: dual isolated 4-20mA current loops with configurable zero/span, 2 SPDT relay contact outputs for high/low disinfectant alarms, and RS485 Modbus RTU communication for long-distance remote telemetry units (RTUs).
Supports documented on-line verification procedures mandated by municipal authorities. Enables regular comparative grab-sample calibration without interrupting continuous baseline monitoring records or causing process loop disruptions.
Enclosed in flame-retardant, high-impact polycarbonate or aluminum die-cast housings rated IP65/NEMA 4X. Corrosion-proof against saline coastal environments, aggressive chlorine gas fumes, and outdoor sun exposure in water facilities.
Comprehensive procurement and technical responses compiled by BOQU’s application and export engineering team.
Cl₂ + H₂O ↔ HOCl + H⁺ + Cl⁻. Amperometric sensors measure HOCl reduction directly because HOCl permeates membranes and reacts on electrodes drastically faster than OCl⁻. At pH 6.5, ~90% of free chlorine is HOCl; at pH 8.0, HOCl drops to ~20%. Without automated pH compensation, a rise in water pH causes amperometric analyzers to report artificially low free chlorine values despite adequate total oxidant capacity. Our controllers utilize real-time pH electrode readings paired with dynamic algorithms to output true Free Chlorine levels.
Equip your municipal water distribution plants, fermentation bioreactors, or automated dosing systems with certified, factory-direct water quality instrumentation.
Direct factory supply for steam-sterilizable biotechnology fermenters, bioreactors, and hot process fluids.
View Specifications →
Equipped with an internationally standardized PG13.5 thread and S8 plug-in head for hassle-free field retrofit.
View Specifications →
Ultra-low trace level monitoring safeguarding thermal power turbines and high-pressure steam boilers against silica scale.
View Specifications →
Precision Total Organic Carbon verification for USP purified water, WFI loops, and deionized water networks.
View Specifications →
Inductive toroidal conductivity system measuring chemical concentrations for food CIP loops and demineralizers.
View Specifications →
Automated wet-chemistry digestion analyzer ensuring continuous municipal and chemical outfall permit compliance.
View Specifications →
Rugged IP65 controller handling pH/ORP inputs with isolated 4-20mA, Modbus RS485, and dual setpoint relays.
View Specifications →
Polarographic dissolved oxygen sensor resistant against harsh steam-in-place sterilization in industrial biopharma fermenters.
View Specifications →