High Temperature (0-130℃) pH Sensor With Temp
Designed for chlorine pools and process loops requiring simultaneous thermal compensation up to 130℃.
Explore Sensor SpecsIndustrial-grade residual chlorine controllers, constant-voltage amperometric electrodes, and multi-channel telemetry transmitters built with ISO 9001 precision.
High-Temp Standard
Designed for chlorine pools and process loops requiring simultaneous thermal compensation up to 130℃.
Explore Sensor Specs
Biopharma Grade
Sanitary grade autoclavable sensor supporting sterile clean-in-place (CIP) and disinfection verification lines.
Explore Sensor Specs
S8 Industrial
Equipped with standardized S8 threaded coupling, PG13.5 mounting, and pressure-resistant electrolyte system.
Explore Sensor Specs
Factory Direct
Bulk wholesale formulation with polymer gel reference to stop electrode poisoning in high active-chlorine pools.
Explore Sensor Specs
Amperometric
Reagentless continuous free-chlorine telemetry with auto-cleaning flow cell, dynamic pH & temp compensation.
Explore Instrument Specs
All-in-One Panel
Simultaneous residual chlorine, pH, turbidity, ORP, and conductivity monitoring engineered for pool manifolds.
Explore Instrument Specs
Shanghai Brand
Engineered for rigorous environments with specialized double-salt bridge to ensure unyielding baseline accuracy.
Explore Sensor Specs
Modbus RTU
Direct RS485 digital output to integrate seamlessly with PLC, DCS, SCADA, or cloud controllers without transmitters.
Explore Sensor SpecsHow state-of-the-art water purification infrastructure balances HOCl/OCl⁻ chemical equilibria, closed-loop telemetry, and PID dosing to achieve fail-safe pathogen mitigation.
Chlorine in water exists dynamically as hypochlorous acid (HOCl) and hypochlorite ions (OCl⁻). HOCl provides up to 80-100 times stronger biocidal efficacy than OCl⁻. Our control systems integrate real-time pH coupled micro-algorithms to continuously optimize chemical dosing based on temperature-adjusted dissociation curves.
Traditional DPD colorimetric analyzers require expensive chemical reagents and 5-15 minute batch sampling intervals, creating dangerous blind spots during shock loads. BOQU constant-voltage amperometric technology delivers continuous, reagentless monitoring with millivolt-level polarization stability.
Preventing chlorine decay while eliminating harmful Trihalomethanes (THMs) and chloramines requires predictive control. BOQU telemetry controllers deploy advanced feedforward-feedback algorithms that modulate sodium hypochlorite dosing pumps or gas chlorinators against fluctuating flow rates.
Operating two advanced manufacturing bases in Shanghai spanning 4,632 m² of specialized production space, BOQU maintains absolute quality control from raw glass blowing to final automated testing.
Our Kangqiao facility houses specialized high-temperature and active chlorine calibration platforms that subject electrodes to extreme pressure and temperature regimes.
Cleanroom electronics manufacturing, in-house SMT surface mounting, and automated multi-gas leak testing eliminate third-party supply chain variabilities.
Every industrial residual chlorine controller and digital electrode completes a rigorous 48-hour continuous signal stress verification prior to packaging.
With an annual output surpassing 100,000 instruments, bulk wholesale procurement cycles drop from Western standard 12-16 weeks to merely 3-7 production days.
Cross-border EPC contractors, municipal utilities, and plant directors demand rigorous conformance to stringent water safety regulations and robust field interchangeability.
Full conformance with WHO Safe Drinking Water Guidelines (requiring residual chlorine ≥0.5 mg/L after 30 mins contact at pH < 8.0), US EPA Surface Water Treatment Rules, and European Drinking Water Directive (EU) 2020/2184.
Pre-configured multilingual firmware (English, Spanish, French, Russian), universal DIN rail/panel-mount sizing, and field-replaceable wear components ensure maintenance simplicity without factory technician redeployment.
Custom software branding, customized protocol mappings (Modbus TCP/IP, Profibus, HART, BACnet), tailored enclosure molds, and white-label sensor sleeve laser etching for Tier-1 water instrumentation brands.
A reference guide to specifying residual chlorine control pools and monitoring systems across critical water processing industries.
| Application Scenario | Critical Target Ranges | Typical Secondary Parameters | Instrument Configuration Recommendation |
|---|---|---|---|
| Municipal Drinking Water Reservoirs | 0.2 – 0.5 mg/L Free Chlorine | pH (6.5 – 8.5), Turbidity (<1.0 NTU) | Amperometric Free Chlorine + MPG-6099Plus Multi-parameter Skids |
| Commercial Aquatic Centers & Pools | 1.0 – 3.0 mg/L Free Chlorine | pH (7.2 – 7.6), ORP (>650 mV), Cyanuric Acid | Constant-voltage Chlorine Sensor + Closed-loop Acid/Hypo Dosing Relays |
| Industrial Cooling Towers & Basins | 0.5 – 1.5 mg/L Total Chlorine | Conductivity / TDS, Corrosion Potential, Temp | Dual Channel DCA130 + Toroidal Conductivity + Biocide Interlock |
| Food & Beverage Sanitation (CIP Wash) | 2.0 – 5.0 mg/L Active Chlorine | pH, Temp, Conductivity (Alkali Strength) | pH5806 High-Temp Sensors + SJG-2083CS Caustic/Acid Meters |
| Wastewater Final Effluent Disinfection | 0.1 – 0.5 mg/L Residual Chlorine | COD, TSS/MLSS, Ammonia Nitrogen (NH₃-N) | ZDYG-2088-01QX TSS + De-chlorination Redox & Trace Cl Analyzers |
| Recirculating Aquaculture Systems (RAS) | < 0.02 mg/L (Total Chlorine Safe Limit) | Dissolved Oxygen (DO), pH, Unionized NH₃ | IOT-485-pH + High-sensitivity Amperometric Trace Cl Alarm Systems |
The convergence of edge AI, digital telemetry, and membrane advancements are transforming municipal pools and industrial disinfection basins.
Traditional static threshold dosing cannot anticipate surge contamination loads. Future controllers integrate embedded neural computing models that cross-correlate historical chlorine consumption, UV index, bathers' density, and raw temperature to dose proactively before water quality falls out of compliance.
Excessive chlorine reacts with organic precursors to generate carcinogenic trihalomethanes and haloacetic acids. The shift towards dynamic, real-time micro-dosing systems ensures continuous pathogen inactivation while maintaining disinfection byproducts (DBPs) far below global regulatory action levels.
Through ultrasonic surface excitation, automated micro-ball agitation, and solid-state electrolyte matrices, modern smart sensors operate maintenance-free for months. Internal microprocessors log calibration decay rates and issue predictive maintenance prompts before false signal drift occurs.
Authoritative technical guidance compiled by BOQU senior instrumentation and water treatment engineers.
Residual free chlorine is comprised of hypochlorous acid (HOCl) and hypochlorite ions (OCl⁻). At pH 6.5, HOCl constitutes ~90% of free chlorine; at pH 8.5, it drops below 10%. Because amperometric electrodes primarily measure molecular HOCl, any pH drift will distort the free chlorine calculation unless dynamic real-time algorithmic pH compensation is applied.
Under standard drinking water or maintained pool circulation with auto-cleaning flow cells, BOQU amperometric platinum electrode heads typically run for 24 to 36 months before resurfacing or replacement. Unlike membrane-covered polarographic probes, there are no delicate Teflon membranes to tear or electrolytes to replenish every month.
Amperometric measurement consumes trace active chlorine molecules at the cathode surface. If the sample water flow rate fluctuates significantly, the polarization boundary layer alters, causing output drift. We engineer constant-head flow assemblies that maintain an unvarying sample flow velocity across the sensor face.
As a source manufacturer, BOQU provides full-scope OEM/ODM solutions: bespoke ABS/die-cast aluminum enclosure tooling, multi-channel MCU firmware modifications, customized baud rates and Modbus register maps, custom laser marking of corporate logos, and custom cable lengths (up to 100m).
Yes. BOQU operates China's first dedicated high-temperature water sensor laboratory. Our specialized high-temperature models (such as the pH5806 and DOG-208FA) endure steam sterilization cycles up to 130℃ at 0.6 MPa, making them ideal for pharmaceutical CIP loops and thermal water circuits.
Every sensor is individual-packed in protective shock-absorbing cases with electrode storage hydration caps. Instruments undergo our 48-hour burn-in trial, standard multi-point factory calibration, and are accompanied by individualized Quality Inspection Certificates conforming to ISO 9001 and CE frameworks.
Integrate our precision analytical transmitters and sensors into your next water project architecture for turnkey operational success.
Factory Wholesale
Direct wholesale from China. Triple ceramic diaphragm structure prevents electrolyte fouling under heavy continuous chlorine loads.
Request Wholesale Quote
Sanitary Build
Pressure-resistant gel formulation, ideal for high temperature sanitation lines and chemical reaction tanks.
Request Wholesale Quote
Standard S8
Universal threaded design, fits seamlessly into European and American immersion sleeves and pipeline flow cells.
Request Wholesale Quote
Bulk Distribution
OEM private-label electrode for global brand water treatment integrators, water parks, and disinfection skids.
Request Wholesale Quote
Transmitter
IP65 waterproof transmitter delivering dual 4-20mA and RS485 Modbus output for closed-loop pool dosing pumps.
Explore Instrument Specs
Dual Channel
Monitor pool pH and dissolved solids on one intelligent console. Perfect for compact dosing panels.
Explore Instrument Specs
Infrared Optics
Infrared scattered-light turbidity sensor ensuring crystal clear pool water and rapid filter breakthrough detection.
Explore Sensor Specs
Bioprocess DO
Autoclavable dissolved oxygen electrode engineered for rigorous biopharma and hot biological treatment tanks.
Explore Sensor Specs