High-Temp (0-130℃) pH & Nitrogen Baseline Sensor
Integrated temperature-compensated electrode built for harsh industrial process verification and bioreactor automation.
View SpecificationsPre-calibrated, industrial-grade electrochemical, optical, and high-temperature sensor configurations engineered in Shanghai for mission-critical monitoring networks.
Integrated temperature-compensated electrode built for harsh industrial process verification and bioreactor automation.
View Specifications
Precision-molded PG13.5 thread with rapid S8 plug connection designed for pressurized biological fermentation streams.
View Specifications
SIP/CIP sterilizable construction engineered for sterile nutrient balance, broth analysis, and protein production.
View Specifications
Anti-fouling solid gel electrolyte sensor minimizing zero-point drift in hyper-saline chemical synthesis streams.
View Specifications
Shanghai Brand certified sensor built to endure repetitive thermal shocks without electrolyte leaching or junction clogging.
View Specifications
Critical companion to nitrification-denitrification processes, maintaining sub-ppm accuracy under hot media conditions.
View Specifications
Onboard microprocessor translating raw microvolts to Modbus RTU, bypassing transmitters for direct SCADA deployment.
View Specifications
Infrared scattered-light sensor with built-in pneumatic wiper system for bio-sludge suspended solids control.
View SpecificationsReactive nitrogen species—encompassing Ammonia Nitrogen (NH₃-N), Ammonium (NH₄⁺), Nitrate (NO₃-N), and Nitrite (NO₂-N)—constitute the primary drivers of eutrophication and ecosystem degradation worldwide. In contemporary municipal wastewater treatment, power generation, and specialized bioprocesses, real-time in-line quantification of nitrogen dynamics is no longer an optional compliance safeguard; it is the fundamental setpoint for dynamic aeration and chemical dosing control.
As global environmental regulators (such as US EPA NPDES, EU Water Framework Directive 2000/60/EC, and China MEP GB 18918 Class 1A) compress permissible total discharge targets down to <1.5 mg/L, conventional offline colorimetric sampling creates dangerous latency. Shanghai BOQU Instrument engineers state-of-the-art solid-state Ion-Selective Electrodes (ISE) and multi-wavelength UV-Vis spectrophotometric sensors, delivering continuous sub-second telemetry directly into distributed control systems (DCS).
Automated cabinet analyzers using salicylic acid or Nessler’s reagent methods demand continuous cooling, high reagent consumption, and periodic waste treatment. BOQU’s field-proven direct insertion IoT Nitrogen probes leverage patent-pending polymer matrix membranes and dual-beam compensation algorithms, delivering:
By integrating micro-electrochemical fabrication, automated Surface-Mount Technology (SMT), and continuous calibration benches under one umbrella, BOQU unlocks an unmatched price-to-performance ratio for international OEMs.
From glassblowing specialized high-temp membranes to PCB potting and optical lens micro-machining, all critical intellectual property and production phases remain strictly in-house across our Lingang and Kangqiao facilities.
We house China’s foremost dedicated high-temperature water quality sensor testing lab, submitting electrodes to pressurized 130°C steam aging to guarantee zero calibration drift in harsh biological fermentation.
With an annual manufacturing capacity exceeding 100,000 analytical instruments, our supply chain ensures predictable delivery windows, custom firmware revisions, and customized mechanics within 10 business days.
Tailored electrode formulations and optical absorption pathlengths suited to aggressive chemistry, heavy biological loads, and extreme thermal conditions.
Online monitoring of NH₄-N and NO₃-N in anoxic/aerobic tanks optimizes nitrification-denitrification rates, lowering aeration electricity costs by up to 25% via feedforward VFD control.
Nitrogen feed optimization directly dictates microbial yield. Our autoclavable, CIP/SIP-stable nitrogen-correlated electrodes ensure batch consistency without risk of bio-contamination.
Un-ionized ammonia (NH₃) is lethally toxic to aquatic fauna at 0.05 mg/L. Our digital probes provide continuous early warning telemetry to trigger automated biofilters and water exchange.
Continuous NO₃-N tracking in closed-loop irrigation balances nitrogen-to-potassium ratios, preventing leaf burn and maximizing growth efficiency in vertical agriculture.
Comprehensive technical specification guide compiled by BOQU application engineers for plant designers, systems integrators, and procurement teams.
| Target Parameter | Underlying Analytical Principle | Standard Range | Dynamic Compensation | Key Process Suitability |
|---|---|---|---|---|
| Ammonia Nitrogen (NH₃-N / NH₄⁺) | Potentiometric Ion-Selective Electrode (ISE) | 0.1 – 1,000 mg/L | pH, K⁺ interference, Temperature | Wastewater biological aeration, RAS fisheries, Municipal effluent |
| Nitrate Nitrogen (NO₃-N) | Direct UV-Vis Absorption (210nm / 275nm) | 0.01 – 100 mg/L | Turbidity (540nm), Organic Carbon | Drinking water plants, River baseline networks, Surface run-off |
| Total Nitrogen (TN) | High-temperature Alkaline Persulfate UV Digestion | 0.05 – 200 mg/L | Reagent-blank auto-zero tracking | Regulatory discharge compliance outfalls, Industrial parks |
| High-Temp Process pH/Redox | Pressurized Polymer Solid Electrolyte | 0.00 – 14.00 pH | Pt1000 RTD embedded thermal loop | Steam sterilization, Bioreactors (0–130°C), Synthetic resins |
| Optical Dissolved Oxygen (DO) | Ruthenium Fluorescent Phase Quenching | 0.00 – 20.00 mg/L | Salinity matrix & Atmospheric pressure | Nitrification reactor control, Fermentation vessels |
Analyzing the transformative shift across North America, Europe, Southeast Asia, and the Middle East toward intelligent, cloud-connected analytical infrastructure.
Global EPCs are abandoning expensive centralized intermediate transmitters. The demand has decisively shifted to "Smart Transducer Heads" featuring native RS485 Modbus RTU or 4-20mA signals capable of wiring directly into PLCs or cellular edge-gateways.
Bio-fouling and algal slime degrade optical windows within days in hot effluents. International buyers consistently specify sensors equipped with integrated mechanical wiper assemblies or pulsed ultrasonic cleaning, reducing routine servicing intervals from weekly to quarterly.
Regulatory frameworks across the EU and North America strictly penalize toxic chemical residues produced by legacy colorimetric monitoring. Solid-state sensing architectures that eliminate potassium persulfate, mercury, or cadmium catalysts represent the highest growing procurement vector.
Sensors deployed in environmental reporting must withstand legal scrutiny. Every individual probe leaving our Shanghai assembly lines undergoes a mandatory 48-hour continuous burn-in and aging test, followed by five-point calibration against NIST-traceable standard buffer solutions.
Operating under strictly audited ISO 9001 and ISO 14001 environmental and quality management systems, our instrumentation holds full European CE compliance, SGS material verifications, and FDA-grade seals for critical sanitary applications.
Continuous signal stability profiling under fluctuating thermal loops to prevent premature field failures.
Certified calibration curves stored digitally inside non-volatile onboard EEPROM for quick deployment.
Precision-sealed titanium or POM enclosures rated for continuous submersion at up to 10 bar process pressure.
Heavy industrial electromagnetic interference screening to preserve sub-millivolt sensing integrity next to heavy VFD pumps.
Critical answers provided directly by our senior sensor chemists and export instrumentation engineers.
Potassium ions possess a similar ionic radius to ammonium (NH₄⁺), which can induce false-positive potentiometric readings. BOQU's advanced multi-parameter nitrogen assemblies integrate a companion Potassium Ion-Selective Electrode and a precision glass pH electrode within the exact same probe head. Our internal processor runs a dynamic matrix algorithm that computes the true NH₃-N concentration across fluctuating chemical environments.
Under continuous industrial sewage deployment, polymer matrix membranes deliver a typical operational lifespan of 12 to 18 months, depending on abrasive suspended solids and grease levels. Because our sensor bodies feature modular replaceable cartridge tips, operators can refresh the membrane module in minutes at a fraction of the cost of full instrument replacement.
Yes. As a pure-play manufacturer based in Shanghai, we provide comprehensive OEM/ODM contracts for overseas instrumentation brands, system integrators, and environmental engineering firms. Customizations include custom molded housings, specific cable lengths and materials (PTFE/PUR), laser engraving, tailored Modbus register maps, and dedicated measuring ranges.
All BOQU smart analytical sensors deliver standard isolated RS485 Modbus RTU communication alongside 4-20mA active outputs. Our probes link seamlessly with local Siemens/Schneider PLCs, edge IoT gateways, or wireless telemetry units (4G/LoRaWAN) without necessitating external transmitter cabinets.
High-reliability online instrumentation, multi-parameter panels, and specialized chemical analyzers manufactured by Shanghai BOQU Instrument.
Compact dual-channel transmitter ideal for fertigation dosing loops, cooling towers, and industrial effluent neutralizing.
View Specifications
Turnkey flow-through panel integrating residual chlorine, turbidity, pH, and conductivity for drinking water security.
View Specifications
Rugged IP65 field-mount transmitter equipped with dual relays, PID dosing logic, and isolated 4-20mA process loops.
View Specifications
Toroidal electrodeless sensor built to quantify chemical regeneration strength, CIP caustic solutions, and mineral acids.
View Specifications
Constant-voltage amperometric cell for continuous, reagentless free chlorine quantification in drinking distribution lines.
View Specifications
Ultra-low sub-ppb colorimetric detection engineered to guard high-pressure power plant steam turbines against silica scale.
View Specifications
680°C catalytic combustion analyzer monitoring organic contamination levels in high-purity pharma and raw inlet waters.
View Specifications
Fully automated cabinet system with internal peristaltic digestion and optical absorption for regulatory EPA outfall reporting.
View SpecificationsWhether you require tailored Modbus firmware for your IoT edge controller, high-temperature SIP-stable electrodes, or full turnkey monitoring cabinets, our engineering teams are ready to support your technical specifications.
Shanghai Boqu Instrument Co., Ltd.
Facility 1: Kangqiao Town, Pudong New Area, Shanghai
Facility 2: Lingang High-Tech Special Area, Shanghai
Direct Inquiries: [email protected]
Technical Direct Line: +86-18916729106