China High Temperature (0-130℃) pH Sensor With Temperature
Rugged glass electrode engineered to withstand high temperatures and rapid thermal cycling in aggressive bio-fermentation process lines.
View SpecificationsPre-calibrated in-house, aged for 48 hours, and integrated with multi-protocol interfaces (RS485 Modbus RTU, 4-20mA) for seamless DCS, PLC, and IoT edge deployments.
Rugged glass electrode engineered to withstand high temperatures and rapid thermal cycling in aggressive bio-fermentation process lines.
View Specifications
Standardized S8 connector geometry providing rapid plug-and-play installation for batch reactors, SIP systems, and pharmaceutical autoclaves.
View Specifications
Heavy-duty electrolyte gel construction resistant to protein poisoning, ionic interference, and extreme hydrostatic working pressures.
View Specifications
Precision biopharma-grade electrode certified for repeatable clean-in-place (CIP) and steam-in-place (SIP) industrial processes.
View Specifications
Awarded Shanghai Brand certification, providing drift-free performance and exceptional longevity under harsh chemical and thermal stresses.
View Specifications
Polarographic dissolved oxygen electrode designed for hot bioprocess broths and critical continuous fermentation bioreactor loops.
View Specifications
Direct RS485 Modbus RTU communication without intermediate transmitters, saving cabinet footprint and wiring overhead in automated sites.
View Specifications
Infrared scattered-light turbidity and TSS analyzer equipped with automatic self-cleaning wipe mechanisms to prevent optical fouling.
View SpecificationsHeadquartered in Shanghai, Shanghai BOQU Instrument operates two modern production hubs (Kangqiao and Lingang) delivering mission-critical instrumentation worldwide.
Year Founded
Production Footprint
R&D & Engineers
Annual Sensor Output
Countries Served
Enterprise Clients
Navigating global regulatory shifts from ISO 7027 and US EPA 180.1 toward autonomous, self-diagnosing optical sensor architectures.
Modern procurement demands strict adherence to photometric compliance standards. Infrared 860nm LED emitters (ISO 7027) mitigate sample coloration interference across wastewater effluents, while tungsten filament light sources (EPA 180.1) satisfy regulatory compliance across North American potable drinking water frameworks.
The instrumentation paradigm has migrated from vulnerable high-impedance analog sensor cables to intelligent edge transducers. With onboard microcontrollers digitizing raw optical signals at the probe tip, process data is converted to Modbus RTU or 4-20mA signals resistant to plant electromagnetic noise.
Biofouling, algae adhesion, and suspended particle crystallization represent the leading failure modes in online turbidity monitoring. Modern industrial transmitters feature integrated mechanical wiper assemblies and pressurized air-wash purge circuits to slash field maintenance cycles.
How global system integrators and EPC contractors specify BOQU turbidity transmitters to secure regulatory compliance and optimize real-time chemical dosing.
Continuous monitoring of raw inlet water, coagulation clarification stages, sand filter effluent, and distribution pumping headers. Sub-0.01 NTU sensitivity enables immediate notification of filter breakthrough and membrane rupture.
Dual-beam infrared absorption configurations accurately report Mixed Liquor Suspended Solids (MLSS) up to 50,000 mg/L in aeration basins, ensuring stable return activated sludge (RAS) and waste activated sludge (WAS) mass balances.
Boiler feed water, steam condensates, and cooling tower circulating circuits demand ultra-trace clarity. Inline turbidity sensors detect iron oxide erosion and resin particulate leaks to protect turbines from severe scale erosion.
Sanitary optical flow cells detect phase separation in broth processing lines and monitor phase change boundaries during Clean-In-Place rinse cycles, significantly reducing valuable product loss and water consumption.
Compare operational boundaries, measurement optics, and engineering specifications for optimal site integration.
| Series Model | Optical Principle | Measurement Range | Resolution / Accuracy | Wetted Materials | Outputs & Protocols |
|---|---|---|---|---|---|
| TB-2088-01 (Low-NTU) | 90° Scattered Light (ISO 7027, 860nm LED) | 0.001 to 40.00 NTU | ±1.5% FS, 0.001 NTU | SS316L, Sapphire Glass, EPDM | 4-20mA, RS485 Modbus, Relay Alarms |
| TB-2088-02 (Industrial) | Dual-Beam 90° & 180° Ratio Method | 0.01 to 4,000 NTU / FNU | ±2.0% FS, 0.01 NTU | Titanium / POM Housing, Sapphire | Isolated RS485 RTU, Programmable Relay |
| TSS-6099 (High Solids) | 135° Backscattered Infrared Detection | 0.0 to 50,000 mg/L (50 g/L) | ±2.5% FS, 1 mg/L | 316L Stainless Steel, PVDF Window | Dual 4-20mA, Modbus RTU, 24VDC/220VAC |
| TB-Sanitary (Food & Bio) | Forward 11° + 90° Dual Scatter Optics | 0.0 to 1,000 NTU / EBC | ±1.0% FS, 0.01 NTU | 316L (Ra < 0.4µm), PEEK, Tri-Clamp | RS485 Modbus, Wireless IoT Option |
Ensuring frictionless site acceptance, third-party audit clearance, and long-term instrument stability across global jurisdictions.
Every turbidity transmitter is assembled under strict ISO 9001 quality management systems. Equipment complies fully with European Electromagnetic Compatibility (EMC Directive 2014/30/EU) and Low Voltage Safety standards (LVD 2014/35/EU).
Instruments undergo NIST-traceable multi-point calibration utilizing primary Formazin standard suspensions. Built-in linearization algorithms correct for detector degradation and ambient temperature fluctuations.
BOQU provides turnkey OEM services to instrumentation brands across Europe, the Americas, and APAC, including custom housing colors, bespoke communication firmware, and dedicated packaging configurations.
Pioneering the transition toward autonomous water treatment via machine-learning predictive maintenance and multi-wavelength spectroscopy.
Next-gen firmware utilizes light scattering gradient dynamics to detect early biofilm formation and optical fogging before measurement drift occurs, automatically scheduling targeted wiper or purge cycles.
Eliminating roadside analyzer panels in remote surface water and environmental monitoring stations through battery-optimized, native cellular IoT and low-power long-range wireless telemetry.
Simultaneous UV254 absorption and multi-angle infrared scattering across a single monolithic optical probe to deliver co-derived COD, TOC, SAC, and turbidity measurements without chemical reagents.
Clear, direct technical responses from Shanghai BOQU's instrumentation engineering team.
Complete instrumentation systems for municipal networks, power plant SWAS, chemical processing, and agricultural dosing loops.
Monitors pH and electrical conductivity simultaneously on a single wall-mount controller, reducing cabinet footprint in RO and cooling towers.
View Specifications
Integrated turn-key panel combining turbidity, residual chlorine, pH, conductivity, and temperature for secondary municipal drinking water stations.
View Specifications
Industrial pH/ORP transmitter engineered with isolated 4-20mA outputs and dual alarm relays for closed-loop neutralization dosing control.
View Specifications
Inductive toroidal conductivity measurement designed for corrosive acid/alkali pipelines and pharmaceutical CIP rinse validation.
View Specifications
Continuous amperometric residual chlorine monitoring for drinking water networks, cooling towers, and municipal disinfection tanks.
View Specifications
Sub-ppb trace wet-chemistry colorimetric instrumentation safeguarding ultra-high-pressure steam boilers and turbines against silica scale deposition.
View Specifications
Direct UV-persulfate oxidation TOC measurement for pharmaceutical purified water (WFI), semiconductor ultrapure loops, and river monitoring.
View Specifications
Automated digestion and colorimetric chemistry systems ensuring continuous environmental compliance reporting at industrial outfalls.
View SpecificationsDirect factory engineering support for OEM custom sensor integration, tender bidding specifications, and custom range calibrations.