ZDYG-2088-01QX Online Turbidity Sensor
Infrared scattered-light turbidity/TSS digital electrode featuring self-cleaning wiper mechanics for heavy industrial effluent and sludge monitoring.
View SpecificationsBuilt under rigorous quality management systems with 48-hour continuous stability burn-in tests and factory ISO 7027 optical calibrations.
Infrared scattered-light turbidity/TSS digital electrode featuring self-cleaning wiper mechanics for heavy industrial effluent and sludge monitoring.
View Specifications
Thermal-resistant electrode with pressurized solid gel electrolyte designed for demanding chemical reactions and hot process pipelines.
Wholesale Pricing
Engineered for steam sterilization resistance up to 130°C within biopharma reactors, holding repeatable zero-drift accuracy.
Supplier Details
Industry-standard PG13.5 mechanical thread and S8 plug design allowing frictionless replacement in international industrial transmitter loops.
Factory Order
Built-in Pt100/Pt1000 RTD sensor ensuring accurate Nernst equation slope compensation during dynamic high-temperature thermal swings.
Direct Inquiry
Shanghai Brand certified sensor engineered for sanitary CIP cycles and live fermentation vessels undergoing repetitive steam sterilization.
Explore pH5806
Dissolved oxygen electrode delivering precise dissolved oxygen feedback loops for aeration and bio-agitation automation control.
View Details
Smart digital bus-isolated sensor communicating Modbus RTU directly into SCADA, DCS, or remote cloud edge units without external transmitters.
Configure SensorFounded In Shanghai
Factory Floor Area
Engineers & Staff
Annual Instrument Yield
Export Destinations
Enterprise Customers
From compliance mandates in potable water networks to harsh chemical sludge monitoring, precision turbidity measurement requires rigorous optical discipline and robust materials science.
Global operations split between two core methods: USEPA 180.1 utilizes a tungsten filament lamp (400-600nm) standard in North America, while ISO 7027 mandates near-infrared 860nm LED emitters. BOQU turbidity electrodes leverage standard 860nm NIR scattering, substantially neutralizing media coloration interference and dissolved organic absorbance.
Traditional single-path sensors suffer baseline degradation due to optical window fouling and LED emitter luminance decay. Modern industrial digital turbidity electrodes integrate dual-beam ratio nephelometric channels (90° scatter combined with 180° transmission reference), mathematically cancelling drift without requiring frequent wet recalibrations.
While nephelometric 90° scattering is supreme under low-range conditions (0–40 NTU / FNU), optical path backscatter and direct 180° light attenuation methods dominate concentrated slurries and activated sludge (up to 50,000 mg/L MLSS), ensuring linear photodiode responsiveness across the entire dynamic span.
How Shanghai BOQU’s dual-facility cluster delivers cost resilience, technical agility, and expedited turnaround for instrumentation EPCs and system integrators.
Unlike regional system repackagers, Shanghai BOQU manages glass blowing, electrode formulation, optoelectronic surface-mount PCB assembly, and CNC housing fabrication under one structural roof across our Kangqiao and Lingang workshops.
With an annual output topping 100,000 instruments, our mass procurement of optical grade sapphire lenses, specialized photodetectors, and POM/316L housings insulates international purchasers from severe global supply chain bottlenecks.
Prior to warehouse dispatch, all turbidity electrodes and high-temperature pH sensors undergo automated 48-hour thermal cycle burn-in and multi-point formazin calibration benchmarks, reducing infant mortality rates on commissioning sites below 0.08%.
Turbidity and process electrodes mapped precisely against demanding liquid matrix chemistry, temperature fluctuations, and maintenance accessibility.
Rapid detection of particulate breakthrough in sand bed and membrane filtration setups. Sensitivity engineered down to 0.001 NTU to maintain WHO compliance.
Continuous activated sludge return (RAS) and clarifier outfall monitoring. Integrated wipers strip biofilms and algae deposits without manual scrubbing.
Broth optical density and cell density accumulation. Withstands continuous in-situ CIP and SIP cycles up to 130°C under high back-pressure operating profiles.
Boiler condensate clarity, condenser leakage detection, and demineralized feedwater safety protecting multimillion-dollar turbine impellers from scaling.
Evaluate measurement topologies, operating boundaries, and data architectures before standardizing project bills of materials.
| Target Parameter | Optical / Chemical Principle | Optimal Process Range | Interference Mitigation | Recommended BOQU Hardware |
|---|---|---|---|---|
| Low Turbidity (Clean) | 90° Nephelometric ISO 7027 (860nm NIR) | 0.001 to 40.00 NTU / FNU | Bubble trap bypass cell; color-blind NIR | ZDYG-2088-01QX Flow-Through Cell |
| Mid-High Turbidity | 90°/180° Combined Dual Scattering | 0 to 4000 NTU | Automatic mechanical silicone wiper blade | ZDYG-2088-01QX Submersible Unit |
| Suspended Solids (TSS) | 180° Light Transmission Attenuation | 0 to 50,000 mg/L (50 g/L) | Pulsed LED high-frequency modulation | Digital TSS Optoelectronic Sensor |
| High-Temp Fermentation pH | High Alkali Glass Membrane + Ag/AgCl Gel | 0.00 to 14.00 pH (Up to 130°C) | Pressurized polymer electrolyte; S8 head | pH5806 Steam-Sterilizable Sensor |
| Multi-Loop Monitoring | Universal Digital Bus Aggregation | Multi-channel bus dependent | Galvanically isolated RS485 circuitry | MPG-6099Plus Analyzer Panel |
How edge intelligence, IoT architectures, and strict municipal accountability are shaping the next cycle of global sensor tenders.
Traditional analog mV or low-level photodiode signals degrade over cable runs exceeding 10 meters due to electromagnetic noise. Modern international plants demand native Modbus RS485 microcontrollers sealed inside the electrode cap, transmitting processed digital data directly to DCS racks without secondary field transmitters.
Industrial users no longer accept unexpected downtime. Next-generation turbidity assemblies analyze optical transmittance losses across the baseline photodiode, warning operators via SCADA alerts when biofilms necessitate an automatic clean cycle before measurement fidelity is compromised.
Procurement directors seek single-source accountability. By partnering directly with Shanghai BOQU, global distributors eliminate intermediate trading markups, acquiring complete turnkey configurations—spanning turbidity, high-temp pH, DO, and conductivity—under unified private labeling frameworks.
Comprehensive technical and commercial insights direct from our export engineering group.
BOQU is a true manufacturer. Founded in 2007, Shanghai Boqu Instrument Co., Ltd. operates two wholly owned facilities in Kangqiao and Lingang, Shanghai (4,632 m² total), with over 200 dedicated staff, complete R&D facilities, clean-room sensor fabrication, and a 100,000+ unit yearly production output.
Our industrial digital turbidity electrodes (such as the ZDYG-2088-01QX) offer integrated motorized mechanical wipers made of durable fluorosilicone. Cleaning frequencies can be customized via RS485 register commands to scrub the optical sapphire window before each measuring burst.
Our smart sensors communicate via standard Modbus RTU protocols over an isolated RS485 physical bus. Furthermore, our standalone industrial analyzer controllers (such as the pHG-2081Pro or DCA130) feature dual galvanic 4-20mA analog loops and programmable SPDT relay alarm outputs.
Yes. BOQU operates China's first specialized high-temperature water quality sensor laboratory. Premium sensors like the Shanghai Brand certified pH5806 and DOG-208FA are built with specialized gel matrices and glass formulations rated for repetitive 130°C SIP cycles in pharmaceutical fermenters.
We provide full white-glove OEM/ODM engineering: laser etched sensor caps, custom cable lengths, custom process connection threads (PG13.5, 3/4" NPT, sanitary Tri-clamp), custom measuring ranges, modified firmware Modbus mapping, and customized display panel branding.
To ensure optimal sensor longevity, please supply: target parameter, measuring range (NTU, mg/L, or pH), process temperature and line pressure, chemical composition (presence of abrasives, organics, or solvents), desired mounting method (submersion, flow cell, or inline pipe), and preferred output signals.
Pre-engineered online analyzers and multi-parameter cabinets delivering turnkey compliance data straight to your control room.
Monitors pH and electrical conductivity simultaneously on a single backlit controller, saving cabinet footprint in RO and cooling towers.
View Specifications
Integrated drinking water skid combining turbidity, residual chlorine, pH, conductivity, and dissolved oxygen with automatic data logging.
System Details
Rugged IP65 field-mount transmitter equipped with isolated 4–20 mA outputs, RS485 Modbus, and programmable PID dosing control relays.
Transmitter Data
Inductive toroidal conductivity technology measuring aggressive acid/caustic concentrations for industrial clean-in-place (CIP) pipelines.
View Meter
Amperometric constant-voltage method maintaining steady disinfection residual compliance without consuming costly wet chemical reagents.
Explore Chlorine
Parts-per-billion trace colorimetric analysis for thermal power plant high-pressure steam and boiler feedwater circuits.
SWAS Solutions
High-precision UV-persulfate digestion measuring trace organic loads across pharmaceutical pure water (WFI) and environmental discharges.
View TOC Analyzer
Automated wet-chemistry micro-digestion analyzers for compliant municipal and industrial wastewater outfall reporting.
Review AnalyzersContact our Shanghai export engineering team today for factory-direct wholesale pricing, OEM private label terms, and custom technical specifications.