Direct manufacturer supply from Shanghai BOQU Instrument: certified high-temperature electrodes, sterilizable bioreactor probes, and intelligent online sensing solutions.
Integrated temperature compensation with specialized high-alkali glass formulation designed for harsh industrial boilers.
Inquire Specifications
Standardized S8/PG13.5 mechanical threading built for pressurized insertion and continuous process line isolation.
Request Factory Price
Steam sterilizable (SIP/CIP resistant) design engineered specifically for biological reactors and pharmaceutical vessels.
View Technical Data
Polymerized solid electrolyte matrix providing exceptional zero-point stability and resistance to chemical poisoning.
Download Datasheet
Awarded the prestigious 'Shanghai Brand', built to withstand extreme autoclaving cycles without loss of slope.
Explore pH5806
Polarographic dissolved oxygen sensor maintaining micro-drift linearity across extended bioreactor aeration profiles.
Inquire DOG-208FA
Smart embedded micro-controller outputting direct Modbus RTU / 4-20mA signals straight to cloud gateways and DCS.
Smart Sensor Spec
Infrared 860nm scattered light sensor equipped with an integrated mechanical wiper for self-cleaning operations.
Wiper Sensor DataWhy modern industrial automation depends on high-resolution Total Dissolved Solids quantification delivered over noise-immune, galvanically isolated current loops.
Total Dissolved Solids (TDS) measures the combined mass of organic and inorganic substances dissolved in water. Because ionic species conduct electrical current, analytical sensors measure specific conductance ($\kappa$ in $\mu\text{S/cm}$ or $\text{mS/cm}$) and dynamically apply an empirical conversion coefficient ($f_{TDS}$, typically ranging from 0.50 to 0.70 based on dominant salt species such as $\text{NaCl}$, $\text{CaSO}_4$, or $\text{NaHCO}_3$):
BOQU industrial TDS transmitters integrate configurable multi-point linearization algorithms that correct for non-linear behavior in high-salinity brines and ultrapure streams alike.
While digital interfaces expand rapidly, the industrial standard 4-20mA current loop remains the undisputed champion of field reliability in industrial automation. Unlike voltage outputs ($0-5\text{V}$ or $0-10\text{V}$) which suffer voltage drop over extended cable runs, current loops deliver zero attenuation over runs exceeding 1,000 meters.
Furthermore, the 4mA live zero provides instantaneous fault detection: a broken wire, dead power rail, or detached electrode drops the loop current to 0mA, prompting DCS alarms immediately without triggering false process commands.
Solution conductivity increases dramatically with temperature—typically between 1.8% to 2.3% per degree Celsius—due to decreasing fluid viscosity and accelerated ionic velocity. Without accurate real-time compensation, a TDS calculation fluctuates wildly simply due to ambient solar exposure on exterior pipes.
BOQU 4-20mA TDS sensors incorporate high-accuracy Pt100, Pt1000, or NTC30K RTDs embedded directly within the sensor's wetted metallic core, guaranteeing millisecond-level thermal synchronization and normalization back to $25^\circ\text{C}$.
How stringent effluent regulations, water reuse mandates, and semiconductor purity specifications drive the international deployment of Chinese high-performance sensing platforms.
With aging municipal water facilities and tightening EPA and EU Industrial Emissions Directive (IED) frameworks, industrial facilities are replacing obsolete analog transmitters with smart, loop-powered transmitters. Key operational drivers include real-time verification of Zero Liquid Discharge (ZLD) effluent loops, cooling tower blowdown optimization to minimize chemical scale inhibitors, and strict monitoring of condensate return lines.
BOQU's 4-20mA TDS sensors deliver high-fidelity diagnostics and extended calibration cycles, driving down the Total Cost of Ownership (TCO) across complex plants.
The Asia-Pacific region, spearheaded by rapid industrialization across Southeast Asia and monumental high-density semiconductor fabrication in Taiwan, South Korea, and Mainland China, consumes unprecedented volumes of ultra-pure water (UPW). In double-pass reverse osmosis (RO) chains, instantaneous TDS tracking before and after membrane stages warns engineers of pinhole membrane ruptures in seconds.
Chinese direct manufacturing capabilities enable fast scaling, rapid spares fulfillment, and custom mechanical designs (Tri-Clamp, NPT, Flanged) that traditional Western vendors struggle to supply on short lead times.
Thermal desalination facilities, multi-stage flash (MSF) evaporators, and deep-well brackish extraction throughout the MENA region require robust wetted materials capable of enduring hypersaline environments exceeding 70,000 ppm TDS. Conventional graphite or low-grade stainless electrodes corrode rapidly due to chloride-induced pitting.
To eliminate these pain points, BOQU supplies electrodeless toroidal inductive TDS sensors featuring PEEK and PVDF encapsulated coils, ensuring maintenance-free performance in high-scaling oilfield produced water.
Achieving measurement accuracy depends entirely on selecting the proper electrode cell constant matched to the physical chemistry of your process water.
| Cell Constant (K) | Effective TDS Range | Electrode Material | Typical Industrial Duty | Mounting Options |
|---|---|---|---|---|
| K = 0.01 cm⁻¹ | 0.005 – 20 ppm (mg/L) | 316L Stainless / Titanium | Power Plant SWAS, Boiler Feedwater, RO Permeate, WFI Loops | 1/2" NPT, Tri-Clamp Sanitary |
| K = 0.10 cm⁻¹ | 0.5 – 200 ppm (mg/L) | 316L Stainless / Platinum | Distilled Water, Pure Steam Condensate, Electronics Rinse | 3/4" NPT Threaded Inline |
| K = 1.00 cm⁻¹ | 10 – 2,000 ppm (mg/L) | Platinum Black / High-Purity Graphite | Potable Water, Commercial Cooling Towers, Hydroponic Nutrient Dosing | 3/4" NPT Immersion or Flow-thru |
| K = 10.0 cm⁻¹ | 200 – 50,000 ppm (mg/L) | Heavy-duty Platinum / Specially Annealed 316L | Brine Streams, Chemical Effluent, Industrial Wastewater Discharge | Flanged or Retractable Valve |
| Toroidal (Inductive) | 100 – 100,000+ ppm (mg/L) | PEEK / PVDF Non-Metallic Body | Raw Sea Water Desalination, Scrubber Bleed, High-Fouling Slurries | Submersible or 2" Triclamp Flow |
When DC or improper AC frequency is passed through conductive fluid, ions migrate to the electrode surfaces, establishing a capacitive boundary layer (polarization resistance) that yields artificially low TDS readings. BOQU 4-20mA TDS sensors utilize adaptive high-frequency bipolar alternating current (AC excitation from 100Hz up to 10kHz), completely neutralizing ionic polarization and eliminating electrolysis gas bubbles on sensor plates.
Industrial steam condensate and boiler monitoring routinely operate under continuous pressures of 1.0 to 1.6 MPa (10 to 16 Bar) paired with temperatures exceeding 100°C. Standard epoxy encapsulations fail via thermal expansion mismatches, allowing moisture to breach internal circuitry.
BOQU implements high-purity glass-to-metal fusion and high-temperature Viton/Kalrez dual O-ring compression assemblies, ensuring total seal integrity even during abrupt pressure shocks.
Depending on panel space and safety classifications, engineers can specify either loop-powered (2-wire, 24V DC carrying both supply voltage and 4-20mA current) or mains-powered (4-wire, isolated 220V AC or 24V DC with dual 4-20mA analog loops + dual SPDT mechanical relays). Two-wire transmitters drastically lower field wiring expenses and integrate natively into Intrinsically Safe (IS) barrier installations across hazardous chemical storage zones.
Real-world integration reviews showcasing how continuous 4-20mA TDS data protects critical assets, ensures regulatory compliance, and slashes chemical operational expenditure.
Challenge: At a 600MW super-critical coal power utility, condenser tube leaks allow raw cooling water to ingress into ultra-pure condensate. Undetected dissolved solids accelerate stress corrosion cracking in turbine blades within hours.
Solution: Installation of BOQU K=0.01 4-20mA low-range TDS/Conductivity transmitters directly on the condensate pump discharge lines.
Outcome: Sub-second detection of cation conductivity and dissolved solid spikes above 0.05 ppm, enabling automated valve trips that dump contaminated condensate before boiler entry, preventing catastrophic shutdowns costing up to $250,000 per incident.
Challenge: Biopharmaceutical manufacturers must prove total absence of caustic soda and acid wash residues in fermenters before starting cell culture batches. Excessive manual sampling causes contamination risks and extends cycle turnaround.
Solution: Implementation of sanitary Tri-Clamp BOQU 4-20mA TDS sensors on vessel drain loops, communicating directly with the batch recipe SCADA system.
Outcome: Automated termination of final WFI (Water for Injection) rinsing precisely when TDS drops below 1.1 ppm (1.3 µS/cm equivalent). Rinsing duration was reduced by 22 minutes per cycle, saving 14,000 liters of pharmaceutical-grade water per batch.
Challenge: Evaporation in industrial cooling towers concentrates dissolved minerals, leading to scaling in heat exchangers. Manual blowdown blowouts waste enormous water volumes, while insufficient blowdown causes heat exchanger plugging.
Solution: Continuous closed-loop automation using heavy-duty K=1.0 graphite 4-20mA TDS sensors controlling pneumatic drain valves.
Outcome: Cooling tower cycles of concentration (CoC) safely raised from 3.2 to 5.0 without scaling, slashing makeup water consumption by 18% while cutting anti-scalant dosing volume by 12 metric tons annually.
Every sensor from Shanghai BOQU Instrument represents complete vertical integration—from raw metal machining and electrode sintering to 48-hour thermal stress testing.
Operating across 4,632 m² of specialized production floorspace between our Kangqiao and Lingang high-tech facilities, BOQU enforces strict incoming material inspection (IQC), in-process SMT automated optical inspection (AOI), and final QA burn-in on every circuit assembly.
Our dual-factory capability guarantees an annual output exceeding 100,000 analytical instruments with traceable production tracking tied to unique laser-etched serial numbers.
To eliminate calibration doubts, every batch of BOQU TDS electrodes is calibrated against standard potassium chloride ($\text{KCl}$) reference solutions traceable directly to the National Institute of Metrology (NIM) and compliant with NIST standard procedures.
Each shipment is accompanied by a certified individual factory calibration certificate detailing determined cell constants, temperature offsets, and linearity verification matrices across five distinct calibration points.
BOQU industrial instruments comply fully with European CE directives (EN 61326-1 for industrial EMC immunity and EN 61010-1 for electrical safety standards), RoHS restriction of hazardous substances, and FDA food-grade biocompatibility standards for wetted polymer materials (PTFE, PEEK, Viton).
Explosion-proof and intrinsically safe designs meet requirements for Ex ib IIC T6 Gb environments, ensuring secure operation in petrochemical refineries and paint shops.
Bridging traditional analog 4-20mA current loops with digital IIoT telemetry, edge AI diagnostics, and self-cleaning hydrodynamic cell design.
The immediate migration path for global chemical plants involves overlaying frequency shift keying (FSK) digital signals directly over existing 4-20mA analog wiring using HART protocol. This empowers maintenance teams to extract multi-variable data—transmitting primary TDS values via analog current while reading process temperature, raw conductivity, and electrode health diagnostics digitally over the exact same copper twisted pair.
Future sensor platforms integrate on-chip electrochemical impedance spectroscopy (EIS). By continuously measuring boundary resistance at varying high-frequency intervals, the internal DSP detects calcium carbonate encrustation, biological slime, or organic fouling before it distorts the primary TDS measurement.
The sensor generates a predictive 'Cleaning Urgency Index' transmitted via 4-20mA NAMUR NE43 status signals, scheduling proactive maintenance before process drift compromises batch quality.
By converging optical refraction technology with multi-frequency inductive coils, next-generation BOQU sensors bypass direct chemical contact entirely. Designed for ultra-viscous chemical media, slurries, and paints, these solid-state units eradicate mechanical fouling points, allowing multi-year deployment without manual re-calibration.
Direct answers from BOQU chief application engineers regarding signal calculation, hardware installation, and overseas delivery frameworks.
For our standard 24V DC loop-powered TDS transmitters, the maximum allowable load resistance ($R_{load}$) is typically 500 Ohms to 650 Ohms. The formula is calculated as: $R_{load} \le (V_{supply} - 12\text{V}) / 0.02\text{A}$. If powering the loop with a regulated 24V DC source, an analog input impedance of 250 Ohms (standard on Siemens or Rockwell PLC analog input cards) operates well within nominal tolerance margins with plenty of head-room for line resistance over lengthy cable runs.
Yes. All BOQU online transmitters and digital smart sensors support on-site field configuration of the TDS factor between 0.40 and 1.00. While standard industrial potable water typically assumes a factor of 0.65 or 0.67, high-purity power plant cycles often utilize 0.50 ($\text{NaCl}$ conversion), and brackish water reverse osmosis operations may demand 0.70. You can program this via the transmitter push-buttons or digitally over RS485 Modbus registers.
In clean water applications (such as RO permeate or potable water), BOQU platinum and 316L electrodes maintain calibration stability for 6 to 12 months without adjustment. In high-fouling, oily, or scaling wastewater matrices, we recommend a 30-day inspection and chemical cleaning cycle (using 5% dilute $\text{HCl}$ for scale removal or a mild surfactant for grease), followed by a single-point or dual-point verification against a certified standard buffer.
Absolutely. Over 35% of BOQU's production volume serves international OEM and ODM contracts. We support fully customized laser-engraved sensor branding, unique housing color schemes, private-label firmware startup screens, tailored cable lengths with custom multi-pin quick-disconnect connectors, and proprietary communication mapping for large system integrators and distributors worldwide.
Contacting electrodes place metallic plates directly in contact with the fluid, making them susceptible to coating by oil, calcium deposits, or biological slime which disrupts electrical measurement. Toroidal (inductive) sensors utilize two magnetic toroids sealed inside a non-conductive fluoropolymer (PEEK or PVDF) housing. Electrical current is induced into the fluid without metal contact, completely eliminating electrode polarization and fouling vulnerability in dirty streams.
All sensors are shipped in custom-molded high-density shock-absorbent EPE foam packaging inside reinforced, moisture-barrier multi-wall export cartons. Liquid-junction and glass electrodes include hermetically sealed electrolyte storage boots containing saturated $\text{KCl}$ solution to keep sensing membranes active during maritime or air transit. Full international export documentation, certificates of origin, and MSDS for buffer solutions are systematically included.
Complete your instrumentation loop with certified online controllers, multi-channel analyzers, and trace chemistry detection platforms from Shanghai BOQU Instrument.
Simultaneous monitoring of pH and electrical conductivity on a single controller; dual isolated 4-20mA outputs.
View DCA130
Turnkey wall-mount system integrating pH, TDS, Turbidity, DO, and Residual Chlorine with centralized data telemetry.
Explore MPG-6099
Rugged IP65 enclosure with programmable dual relay controls and galvanic 4-20mA current transmission for dosing.
Inquire pHG-2081Pro
Inductive conductivity analyzer designed for continuous concentration monitoring of chemical baths, CIP acid, and caustic.
View SJG-2083CS
Reagent-free continuous chlorine tracking with automatic pH compensation for potable networks and cooling disinfection.
Residual Chlorine Spec
Sub-ppb level colorimetric wet-chemistry monitoring engineered specifically for power generation boiler protection.
SWAS Trace Chemistry
UV-persulfate catalytic oxidation method providing accurate TOC verification in pharmaceutical and high-purity water.
TOC-3042 Details
Automated digestion spectrophotometry for municipal and industrial wastewater discharge compliance reporting.
Discharge Monitor DataDirect supply pricing, comprehensive OEM specifications, and metrological calibration certificates available on-demand from Shanghai Boqu Instrument Co., Ltd.